7.7 TROUBLESHOOTING GUIDE (CONTINUED)
SYMPTOM
PROBABLE CAUSE
REMEDY
HI T1, HI T2 MESSAGE (cont.)
Discharge Temperature Exceeded
235
_
F (113
_
C) Because:
Fluid Level in Sump is Too Low
Check/correct fluid level.
Thermal Valve Malfunctioned
Check/replace thermal valve.
Cooler Fins are Dirty
Clean cooler fins.
Water Flow is Low (water--cooled
Check cooling water supply (i.e.,
packages only)
closed valves).
Water Temperature is High (water--
Increase water flow, lower water
cooled packages only)
temperature.
Cooler is Plugged (water--cooled
Clean tubes and/or shell -- if tube
packages only)
plugging persists, provide cleaner
water.
Temperature RTD Malfunction
Check connections from RTD.
If adequate, replace RTD.
HI P1, HI P2 MESSAGE
Discharge Pressure Exceeded
Shutdown Level Because:
Unloading Device (i.e., blowdown
Check operation of unloading device
valve, Sullicon actuator, optional
See Section 7.5.
spiral valve) failed to operate
Pressure Regulator Maladjusted
Check operation of pressure regulator
See Section 7.5.
Solenoid Valve Failed
Check operation of solenoid valve
to Operate
See Section 7.5.
Control Air Signal Leaks
Check tubework feeding control
signal for leaks.
Control Air Signal Filter Clogged
Service filter assembly
See Section 7.5.
T1 HI MESSAGE
Discharge Temperature Exceeded
225
d
F (107
d
C) for Pre--Alarm
Discharge Temperature Exceeded
235
d
F (113
d
C) for Shutdown
Ambient Temperature Exceeded
Improve local ventilation (i.e.,
105
d
F (41
d
C)
remote intake of process and/or
cooling air.
Fluid Level in Sump is Too Low
Check/correct fluid level.
Thermal Valve Malfunctioned
Check/replace thermal valve.
Cooler Fins are Dirty
Clean cooler fins.
Water Flow is Low (water--cooled
Check cooling water supply (i.e.,
packages only)
closed valves).
Water Temperature is High (water--
Increase water flow, lower water
cooled packages only)
temperature.
Cooler is Plugged (water--cooled
Clean tubes and/or shell -- if tube
packages only)
plugging persists, provide cleaner
water.
Temperature RTD Malfunction
Check connections from RTD.
If adequate, replace RTD.
P1 HI MESSAGE
P1 MAX -- 3psi (.2 bar) Exceeded for
Pre--Alarm
P1 MAX Exceeded for Shutdown
Discharge Pressure Exceeded
Shutdown Level Because:
Unloading Device (i.e., Blowdown
Check operation of unloading device.
Valve, Sullicon Actuator, Optional
Spiral Valve) Failed to Operate
Summary of Contents for LS-20S
Page 6: ...NOTES...
Page 23: ...Section 3 SPECIFICATIONS 17 Figure 3 1A Identification Air cooled Model Prior to June 1 2000...
Page 24: ...Section 3 SPECIFICATIONS 18 Figure 3 1B Identification Air cooled Model After June 1 2000...
Page 25: ...Section 3 SPECIFICATIONS 19 Figure 3 1C Identification Water cooled Model...
Page 26: ...20 NOTES...
Page 31: ...25 NOTES...
Page 76: ...Section 8 PARTS LIST 70 8 16 ELECTRICAL BOX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...
Page 84: ...Section 8 PARTS LIST 78 8 20 DECAL GROUP 1 2 3 4 5 6 7 8 9 10 11 12 13 14...
Page 86: ...Section 8 PARTS LIST 80 8 20 DECAL GROUP 15 16 17 18 19 20 21 22 23 24...
Page 88: ...Section 8 PARTS LIST 82 8 20 DECAL GROUP 25 26 27 28 29...
Page 90: ...Section 8 PARTS LIST 84 8 20 DECAL GROUP 30 31 32...
Page 92: ...Section 8 PARTS LIST 86 8 21 DECAL LOCATIONS 1 2 3 4 5 6 7 8 9 10 12 11 15 16 17 18 12 13 14...
Page 94: ...Section 8 PARTS LIST 88 8 21 DECAL LOCATIONS 9 1 2 3 4 5 6 7 8 10 11 WATER COOLED MODEL 12 13...
Page 96: ...Section 8 PARTS LIST 90 8 21 DECAL LOCATIONS 1 2 3 5 6 7 4...
Page 98: ...Section 8 PARTS LIST 92 8 22 WIRING DIAGRAM STANDARD FULL VOLTAGE SUPERVISOR II DELUXE...
Page 99: ...Section 8 PARTS LIST 93 8 23 WIRING DIAGRAM STANDARD WYE DELTA SUPERVISOR II DELUXE...
Page 100: ...Section 8 PARTS LIST 94 8 24 WIRING DIAGRAM STANDARD WYE DELTA SUPERVISOR II DELUXE EUROPE...
Page 101: ...NOTES...