XT
-
VISION
J
OYSTICK CONNECTION UNIT
B14.2
N
AME
:
T
RAINING DEPARTMENT
D
ATE
:
04/2018
P
AGE
:
74/109
REFERENCE:
TECHNICIAN’S
OPERATING
MANUAL
POLYVRAC
XT
VISION
I
ND
02
2.
MAX setting:
a)
Supply the machine's hydraulic unit with a tractor rate which
corresponds to the spreading system's requirements, i.e.:
50 to 55 l/min (BOOM)
55 to 60 l/min (WET BULK DISK 125 cm3 motor, with or
without BOOM)
70 to 75 l/min (GRANULATED DISKS 125 cm3 motor, with or
without BOOM and WET BULK DISKS)
b)
Place the potentiometer on the handle to full rotation in
engaged direction.
c)
Set the handle switch to spreading position to run the
spreading system motors.
d)
Act on the "MAX" potentiometer until the following rotation is
gradually obtained:
S
PREADING SYSTEM
R
OTATION RATE
Booms only
190 rpm (+/- 20)
Wet Bulk disks with or without booms
430 rpm (+/- 30)
Granulated disks with or without wet
bulk booms / disks
540 rpm (+/- 30)
(Check it using a tachometer, following the general safety instructions,
or using the electronic console).
The spreading system motor maximum rate is now set:
3.
Acceleration/deceleration boom setting
This applies the setting for the spreading system motor rotation start-
up and shutdown, in particular with booms, in relation to the slope
lifting and lowering during "field end" function.
a)
Make sure that the selector button on the connection unit is in
boom position.
b)
Activate the "field end" stoppage function on the handle and
act on the "BOOM" potentiometer until the motors stop when
the slopes lift.
c)
Activate the "field end start" function on the handle and make
sure that the motors start rotating immediately as the slopes
are lowered.
The "field end" function is now set.