![Sulky Polyvrac XT 100 VISION Technician'S Operating Manual Download Page 72](http://html1.mh-extra.com/html/sulky/polyvrac-xt-100-vision/polyvrac-xt-100-vision_technicians-operating-manual_1390245072.webp)
XT
-
VISION
T
HE
CAN
MODULE
B13.2
N
AME
:
T
RAINING DEPARTMENT
D
ATE
:
04/2018
P
AGE
:
72/109
REFERENCE:
TECHNICIAN’S
OPERATING
MANUAL
POLYVRAC
XT
VISION
I
ND
02
3.
Diagnostic LED:
The ECU is equipped with a diagnostic LED:
R
EF
.
N
AME
C
OMMENTS
①
STATUS
Flashing red => CAN link ok
Fixed red => Under voltage but no CAN link
The diodes marked
OP
light up in red when the actuator is commanded
②
OP 1
ECONOV:
Left spout actuator rod out
OP 2
ECONOV:
Left spout actuator rod in
③
OP 3
ECONOV:
Right spout actuator rod out
OP 4
ECONOV:
Right spout actuator rod in
④
OP 5
TRIBORD:
Tribord actuator rod out
OP 6
TRIBORD:
Tribord actuator rod in
⑤
OP 7
AUTO BOOM VALVE:
Left actuator actuator rod out
OP 8
AUTO BOOM VALVE:
Left actuator actuator rod in
⑥
OP 9
AUTO BOOM VALVE:
Right actuator actuator rod out
OP 10
AUTO BOOM VALVE:
Right actuator actuator rod out