XT
-
VISION
C
ONNECTION TO THE
M
ATRIX
P
RO
GUIDE BARS
A3.5.3
N
AME
:
T
RAINING DEPARTMENT
D
ATE
:
04/2018
P
AGE
:
19/109
REFERENCE:
TECHNICIAN’S
OPERATING
MANUAL
POLYVRAC
XT
VISION
I
ND
02
4-
Validate the forward movement speed
In the
REG
menu select
Select
with the
keys and validate with
.
There is no speed calibration (over 100m) to be made. The
speed is automatically correct.
5-
The GPS reception may be checked:
In the
INFO
menu, press
then
Smart boom connection plan:
S
MART BOOM
RS
232
PLUG
P
IN
C
OLOUR
F
UNCTION
3
Brown
TX
4
Green
RX
(NMEA signal)
8
White
0 V
S
MART BOOM
7-
PIN PLUG
P
IN
C
OLOUR
E
CONOV FUNCTION
1
Pink
L external section
2
Blue
L central section
3
White
L internal section
4
Brown
R internal section
5
Green
R central section
6
Yellow
R external section
Grey
0 V