XT
-
VISION
R
EPLACEMENT OF A WEIGHING SENSOR
B12.2
N
AME
:
T
RAINING DEPARTMENT
D
ATE
:
04/2018
P
AGE
:
70/109
REFERENCE:
TECHNICIAN’S
OPERATING
MANUAL
POLYVRAC
XT
VISION
I
ND
02
The sensors must be mounted to the spreader with the
machine empty and coupled to the tractor.
c)
Position the sensor(s) on the machine. Tighten the screws
alternately by 1/8 turn monitoring the signal.
The signal must
remain within the range 2.5
0.5 V
Tighten the screws
to 30 Nm of torque
d)
Set the sensor OFFSET to 4.0 V
Display the channel of the sensor concerned with button ①. The LED
IN1
– (boom),
IN2
(axle 1) and
IN3
(axle 2) lights up green when the channel is selected. The display indicates the voltage for the
channel sensor concerned.
Press button ②, the
"Zero"
indicator lights up red. Using button ③, increase the display's value to
4.0
(1 press = 0.5)
Press button ② again. The
"Gain"
indicator lights up red. Make sure that the value is at 1.0. If it is not,
correct it with button ③
To save the OFFSET, press and hold button ①. While saving, the channel's LED flashes and the display
shows two dashes.
Do the same for the other sensors if necessary
e)
Disconnect the connection unit
f)
Run the sensor cables
g)
Connect the sensors to the CAN Module connection unit
h)
Carry out a full weighing calibration (see file B11)