April 13, 2009
115-V 20-Amp 60-Hz Self-Timed Unit
8
TESTING AND OPERATION
After the mounting and all connections are complete, test the SUITMATE
®
unit as follows:
1) Make certain all packaging material is removed from the unit including material around the Motor.
2) Check to see that the Basket is empty and that the Lid moves freely.
3) Press down on the Lid. The unit will start and run for 8 seconds. While the unit is running it should run
smoothly and there should be no excessive vibration or noise.
4) Releasing the lid before the unit automatically stops causes the Basket to stop within one (1) second.
5) Test the SUITMATE
®
unit by putting a wet swimsuit in the unit according to the instructions on the underside
of the Lid. If there is excessive vibration or noise it is usually caused by the improper loading of the
swimsuit. Be certain that the swimsuit is pushed to the bottom of the Basket and that all material is at least
two inches below the top of the Basket.
INSTALLATION TROUBLESHOOTING
If the SUITMATE
®
unit does not operate, check the following:
1) Check to see if there is power to the unit. Check the circuit using an A.C. voltmeter set to the appropriate
range; measure across the “LINE” side of the GFCI.
2) Make certain that the GFCI switch is in the “ON” position.
3) Check the connections on the GFCI Junction Box. Be certain there is power on the “LOAD” side of
the GFCI.
4) Check the SUITMATE
®
UNIT TROUBLESHOOTING section in this manual for additional troubleshooting
assistance.
FINISHING THE INSTALLATION
Be certain to save this SUITMATE
®
UNIT MANUAL for future reference. If you have any concerns about the
correct installation of the SUITMATE
®
unit, please contact Extractor Corporation at: (Telephone) 800-553-3353,
(Fax) 847-742-3552, or (E-Mail) [email protected].
With proper installation, use, and maintenance your SUITMATE
®
Swimsuit Water Extractor will provide you
with years of trouble-free service.
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115
Summary of Contents for Swimsuit Water Extractor
Page 2: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 70: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 71: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 72: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...