![Suitmate Swimsuit Water Extractor Installation & Maintenance Manual Download Page 49](http://html1.mh-extra.com/html/suitmate/swimsuit-water-extractor/swimsuit-water-extractor_installation-and-maintenance-manual_1390102049.webp)
April 13, 2009
115-V 20-Amp 60-Hz Self-Timed Unit
47
ELECTRICAL ASSEMBLIES
115-V 20-Amp 60-Hz Self-Timed Unit
GENERAL
When servicing the SUITMATE
®
unit, observe the following safety precautions:
Always turn off the power at the circuit breaker – place a lockout tag on the circuit breaker panel indicating that
the breaker is not to be turned on except by authorized personnel – and disconnect the unit before doing any
work on the SUITMATE
®
unit. Simply turning off a switch is NOT enough.
Use only proper tools, test equipment, and work practices when servicing the SUITMATE
®
unit. If there are any
questions concerning proper tools, equipment or practices, please contact the factory for recommendations at:
(Telephone) (800) 553-3353, (Fax) 847-742-3552, or (E-Mail) [email protected].
Due to critical tolerances, use only specified replacement parts. See the SUITMATE
®
UNIT PARTS AND
ASSEMBLIES list in this manual.
REMOVE AND REPLACE GFCI
The GFCI can be serviced from the bottom of the unit without removing the unit from the wall.
Do this FIRST
Make certain you have all the correct parts and fasteners necessary for correct installation. Parts used in this
process: (1) AEC2009 GFCI 115V 60Hz.
REMOVE GFCI
1) Turn off the main electrical power to the unit – place a lockout tag on the circuit breaker panel indicating that
the breaker is not to be turned on except by authorized personnel, and disconnect the unit before doing any
work on the SUITMATE
®
unit. Simply turning off a switch in NOT enough.
2) Remove the cover of the weatherproof Junction Box that contains the GFCI. Set the cover and (2) screws
aside for reassembly.
3) Remove the GFCI from the weatherproof Junction Box by removing the (2) GFCI mounting screws.
REPLACE GFCI
1) Remove the wires, one at a time, and put each wire in the matching position on the new GFCI.
2) Place the newly wired GFCI into the weatherproof Junction Box and secure it.
3) Replace the cover of the weatherproof Junction Box using the (2) screws previously removed.
4) Turn on the main electrical power to the unit and retest to assure proper operation. Refer to TESTING AND
OPERATION on page 8.
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115
Summary of Contents for Swimsuit Water Extractor
Page 2: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 70: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 71: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 72: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...