April 13, 2009
115-V 20-Amp 60-Hz Self-Timed Unit
25
REMOVE RISER CABLE ASSEMBLY
Do this FIRST
Make certain you have all the correct parts and fasteners necessary for correct installation. Re-use any
components that are not damaged, otherwise replace them. Parts used in this process: (2) AEC1807
Turnbuckle Nut, (1) EC8 Riser Cable Assembly, (2) AEC1831 Machine Screw, (1) AEC1245 Micro Switch Box
Cover. Plus any components required to reinstall the Sub-Top and Top Assemblies (Page 19).
REMOVE RISER CABLE ASSEMBLY
1) Remove SUITMATE
®
unit from the Wall Mount Bracket. See instructions beginning on Page 17.
2) Remove Top and Sub-Top Assemblies. See instructions beginning on Page 19.
3) Place the SUITMATE
®
unit in an upright position with the back of the unit facing out.
4) Remove the Micro Switch Box Cover. The cover is held on with (2) Machine Screws. Remove the cover and
screws and set aside for reassembly.
5) Remove the Turnbuckle Nut from the Turnbuckle.
6) Pull the Turnbuckle up and out of the hole in the Micro Switch arm.
7) Remove the Riser Cable by pulling it up through the conduit connector at the top of the unit.
REPLACE RISER CABLE ASSEMBLY
1) Reinstall Sub-Top Assembly after cleaning out any debris before starting with the Riser Cable replacement.
2) Drop the new Riser Cable (with Turnbuckle) down through the conduit to the Micro Switch.
3) Insert the Turnbuckle through the hole in the Micro Switch arm. Replace the Nut (saved from step 5 above)
on the Turnbuckle.
4) Insert the Turnbuckle on the new Riser Cable through the hole in the Riser Shuttle. Replace the
Turnbuckle Nut.
5) Replace Top Assembly. See instructions beginning on Page 21.
6) Push the Lid down. The Micro Switch should NOT activate (click) until the Lid is approximately ¼-inch from
being totally depressed. Adjust the alignment by tightening (clockwise – will activate unit sooner) or
loosening (counter-clockwise – will activate unit later) the Turnbuckle Nut on the bottom of the Riser Cable
until the proper adjustment is obtained. Do not bend the Micro Switch arm. For additional information refer to
the MICRO SWITCH ADJUSTMENT PROCEDURE (on Page 59) section in this manual.
7) Provide power to the unit to make certain it is functioning properly, test it.
8) Disconnect power to the unit.
9) Replace the Micro Switch Box Cover securing it with the (2) Machine Screws removed in step 4 above.
10) Reinstall the SUITMATE
®
unit to the Wall Mount Bracket. See instructions beginning on Page 18.
11) Retest the SUITMATE
®
unit for proper operation, refer to TESTING AND OPERATION on Page 8.
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115
Summary of Contents for Swimsuit Water Extractor
Page 2: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 70: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 71: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 72: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...