April 13, 2009
115-V 20-Amp 60-Hz Self-Timed Unit
5
To secure the Wall Mount Bracket, center the bracket at the desired location and mark the locations of the two
center holes. Secure the Wall Mount Bracket at the center holes using fasteners appropriate to your conditions.
All fasteners must be capable of supporting 55 pounds (25kg) in addition to the added weight or pressure of
people leaning on the unit. Make certain the Wall Mount Bracket is level. Next secure the outer holes of the
Wall Mount Bracket to the structure using fasteners appropriate to your conditions. After the bracket has been
properly anchored to the wall and the electrical and drainage requirements have been allowed for, the
SUITMATE
®
unit is ready to be mounted to the wall.
Mounting the SUITMATE
®
Unit to the Wall
Remove the SUITMATE
®
unit from its shipping box. Remove and discard the packaging material that is
protecting the SUITMATE
®
unit. The upper back lip of the SUITMATE
®
unit should be lowered down and
centered on the Wall Mount Bracket. After the unit is centered, push down on the back of the unit to make
certain that it is securely wedged onto the bracket. Make certain the unit is level. If it is not level, remove the
unit, adjust the Wall Mount Bracket and re-hang the unit. A level installation is necessary to minimize vibration
and insure proper drainage of wastewater. Finish securing the unit to the wall using appropriate fasteners and
anchors on the lower mounting channel at the bottom rear of the unit. This will prevent the unit from being lifted
from the bracket or being moved.
Note:
Several holes in the lower mounting bracket may be obstructed by the GFCI Cover. Remove the GFCI
cover to provide access to these holes.
CUTAWAY VIEW OF SUITMATE
®
UNIT
FLOOR
PRESS HERE TO FIRMLY
SET SUITMATE
®
UNIT
WALL
WALL
MOUNT
BRACKET
UPPER
BACK
LIP
EASE
UNIT
OVER
BRACKET
AND
LOWER
MOUNTING
SCREWS
SUITMATE
®
UNIT
SUITMATE
®
UNIT
WALL
WALL MOUNT
BRACKET
USE APPROPRIATE ANCHORS AND
FASTENERS TO MOUNT THE UNIT
FOR YOUR SPECIFIC INSTALLATION
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115
Summary of Contents for Swimsuit Water Extractor
Page 2: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 70: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 71: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Page 72: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...