KEY DISPLAY
The four digit display on the upper cover of the battery shows the percentage of remaining
battery power, for example :
Display 100 = 100% of the charge
Display 70 = 70% of the charge
In addition to the percentage of charge remaining, it displays also the error codes.
Please refer to the table below.
code
event
What to do
A001
charger is not suitable or
damaged, the battery is in
protection mode
the battery should be checked and restored at the service
center Suex
A002
the battery has been
discharged with an
excessive current
the battery must be checked and restored at the service
center Suex, must check because the load was excessive,
also check the ADV and verified if it has been used for
other purposes than its intended
A003
overheating power stage
automatic reset to the cooling of the battery pack
A004
overvoltage
at least one cell has exceeded the maximum allowable
voltage, the system self-resets lowering of the voltage
A005
short circuit during the
charging phase
the battery must be checked and reset at a service center
Suex, must also be checked charger used
A006
short circuit in the
discharge phase
the battery should be checked and restored at the service
center Suex, should be checked also the 'ADV
A007
cut-off for battery too low
the system self-resets the subsequent charging of the
battery
A008
error BMS
probable failure of the BMS must be replaced exclusively
by Suex
A009
overheating control logic
automatic reset to the cooling of the battery pack
A010
battery no longer usable
excessive discharge of the cells, battery out of use,
service only exclusively Suex