10596
TO ENSURE YOUR USER INFORMATION IS UP TO DATE PLEASE DOWNLOAD THE LATEST VERSION OF THIS MANUAL FROM WWW.SUEX
Page 24 of 43
24
ADV
FLOODING
,
SINKING
This could occur especially due to improper use, a collision, incorrect
closing or inefficient maintenance.
In the event of flooding, the scooter will start to tilt downward and thus
sink.
In the event of
total
flooding, the situation could become
POTENTIALLY
HAZARDOUS since the ADV will start to SINK, DRAGGING YOU DOWN
and therefore
the vehicle
MUST BE IMMEDIATELY ABANDONED.
25
C
LEANING AND STORAGE
After use, the ADV must be rinsed thoroughly with fresh water. A neutral detergent may be
used for more stubborn dirt. Before opening the ADV, it is important to remove all traces of
salt. In particular, the magnetic reed connected to the trigger must be cleaned thoroughly
and all grit and sand particles removed.
Do not use any solvents or petroleum-based products.
The ADV must be stored in a cool, clean, and ventilated place, in an
upright position with the nose facing upwards. The battery must be
removed, charged and stored away from frosty conditions or excessive
heat. Make sure that the connectors do not come into contact with metal
objects inside the ADV or the battery will be shorted. The wheel for
opening the head cap must be loosened such that the gasket is in view.
Important note:
always remove the battery after the use.
26
M
AINTENANCE
Lubrication of head cap O-ring case
Open the ADV, gently remove the lock O-ring (19) (see fig. 6) being careful not to scratch
the O-ring support surfaces, and clean the seating thoroughly (only by means of a clean
brush or soft cloth). Do not use any type of solvent or alcohol. Apply silicone oil to the O-
ring and return it to its place. Do not use any other type of oil!!! We recommend the aerosol
spray type which is usually used for diving equipment. Occasionally, lubricate the lock
knob screw with normal mineral grease. Never lubricate trigger or magnetic piston
movement. They would fill of sand and dirt. Do not lubricate electrical contacts!
Closing knob gasket maintenance
Whenever the closing knob (9) (see fig. 1) comes into contact with sand, rinse with running
water before rotating it. About every 50 uses, remove it, using pliers, clean the gaskets
and lubricate with silicon oil, If you are not familiar with this operation, contact an
authorized service centre.