- 7 -

Repeat this procedure as often as needed to reduce the frequency of the weeping 

of the P & T Valve. If the weeping persists after following this procedure, you may 

elect to install an expansion or accumulator tank in the cold water line between 

the tank and check valve to relieve the pressure caused by thermal expansion. 

Contact your local dealer for assistance.

REMOVING WATER HEATER

1. 

Shut off gas supply and disconnect gas supply line from water heater.

2. 

On all Electric Models, turn off electrical supply then disconnect 120 V.A.C. 

supply at junction box mounted on heater.

3. 

On all DSI Models, disconnect 12 V.D.C. power supply at junction box on heater.

4. 

Disconnect all wires at module board.

5. 

Shut  off  water  supply.  Drain  water  from  tank  following  instructions  under 

“Draining and Storage”.

6. 

Disconnect hot and cold water lines from water heater.

7. 

Remove screws or nails securing control housing to framed opening.

8.

  Slide heater out. To reinstall, follow instructions in manual under “Installation 

Instructions”.

Figure 5

120 V.A.C. ONLY

CODE

BLACK

BK

COLOR

W WHITE

HI-

LIMIT

T'STAT

BK

BK

BK

SWITCH

BK

W

DISCONNECT POWER SUPPLY BEFORE REMOVING COVER

RELAY

BK

*

SUBURBAN MANUFACTURING COMPANY, DAYTON, TENNESSEE

120 V.A.C SINGLE PHASE - 1440 WATT ELEMENT - 60 CYCLE

TOTAL CONNECTED WATTS = 1440 - AMPS = 12

GROUNDING SCREW

ELECTRIC

ELEMENT

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE HEATER MUST

BE REPLACED, IT MUST BE REPLACED WITH 14 GA. 105°C WIRE OR

EQUIVALENT.

SI UN DES FILS ELECTIQUES LIVRES AVEC LE CHAUFFE-EAU DOIT 

ETRE REMPLACE, UTILISER A CET EFFET UN FIL 14 GA. 105° OU 

EQUIVALENT.                       *120VAC SIDE OF RELAY                        

340540

12 V.D.C. ONLY

JUNCTION

BOX

Y

G

BL

R

RED

BLUE

GREEN

YELLOW

BROWN

BR

BK BLACK

G

BL

R

R

Y

BK

1

2

3

4

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE WATER

HEATER MUST BE REPLACED, IT MUST BE REPLACED WITH 18 GA.,

105°C WIRE OR EQUIVALENT.

SWITCH

HI-LIMIT

T'STAT

MODULE BD.

SPARK CABLE

ELECTRODE

BR

GAS VALVE

SWITCH

(             FACTORY WIRING)
( ---- FIELD WIRING)

DISCONNECT POWER SUPPLY BEFORE SERVICING THERMOSTAT 

AND HI-LIMIT UNDER ACCESS COVER.

                                                      

1 3 4 6

                                     *12VDC SIDE OF RELAY                             340539

LIGHT

RELAY

O ORANGE

O

(GAS)

(ELECTRIC)

CAUTION: DO NOT HI-POT (DIELECTRIC HIGH VOLTAGE TEST) THIS 

UNIT AFTER INSTALLATION. TO DO SO MAY CAUSE COMPONENT 

DAMAGE AND VOIDS WARRANTY OF WATER HEATER.

Figure 4

HOT

COLD

Figure 6

PARTS AND SERVICE

Contact a conveniently located recommended Suburban Service Center. 

 

Describe to them the nature of your problem, make an appointment, if necessary, 

and provide for delivery of your RV with the appliance installed.

To obtain information on locating a local service agency, contact:

 

AIRXCEL, Inc., Suburban Division

 

Customer Service Department

 

676 Broadway Street

 

Dayton, TN   37321

 

(423) 775-2131 Ext. 7101

 

www.Airxcel.com

CAULK AND SEAL GROMMET (INCLUDING SLIT

AND TUBING) ALL AROUND AIR TIGHT

GAS VALVE

CONTROL HOUSING

ILLUSTRATED SHOWING

INSIDE OF HOUSING

GROMMET

(GAS INLET)

Figure 7

RESET

ON

ELECTRIC

GAS

ON

WATER HEATER

SWITCH, LAMP AND PLATE ASSEMBLY

(GAS AND ELECTRIC)

Figure 8

RESET BUTTON

12 V.D.C. T-STAT

HI-LIMIT

Figure 9

Figure 10

120 V.A.C. T-STAT

HI-LIMIT

RESET BUTTON

Summary of Contents for SW10DEL

Page 1: ...HEATER IF SUBJECT TO FREEZING TEMPERATURES WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITI...

Page 2: ...ter before operating the water heater Operation of the water heater without water in the tank may result in damage to the tank and or controls This type of damage is not covered by the limited warrant...

Page 3: ...FRAMED OPENING FLOOR Figure 1B FRAMED OPENING DETAIL A SPECIAL SCREW CONTROL HOUSING GASKET DOOR LATCH CONTROL HOUSING FLUSH MOUNT DOOR CAULK AROUND OPENING FRAMED OPENING SEE FIGURE NO 1 EXTERIOR COA...

Page 4: ...H MOUNT DOOR FRAME WITH GASKET DC JUNCTION BOX DOOR LATCH SW10DEL SW12DEL SW16DEL Figure 2A A FRAMED OPENING DETAIL A SPECIAL SCREW CONTROL HOUSING GASKET DOOR LATCH RADIUS CORNER DOOR FRAME CONTROL H...

Page 5: ...ight If not tightly sealed moisture and potential harmful flue products could vent through opening and into living area of trailer See Figure 7 B Turn on gas and check all fittings and connections for...

Page 6: ...closed off out of the system in the bypass position particularly if you are introducing antifreeze into the plumbing system Antifreeze can be very corrosive to the anode rod creating premature failure...

Page 7: ...05 C WIRE OR EQUIVALENT SI UN DES FILS ELECTIQUES LIVRES AVEC LE CHAUFFE EAU DOIT ETRE REMPLACE UTILISER A CET EFFET UN FIL 14 GA 105 OU EQUIVALENT 120VAC SIDE OF RELAY 340540 12 V D C ONLY JUNCTION B...

Page 8: ...CLEARANCE TO VENTILATED SOFFIT LOCATED ABOVE THE TERMINAL WITHIN A HORIZONTAL DISTANCE OF 2 FT 61cm FROM THE CENTER LINE OF THE TERMINAL M CLEARANCE UNDER VERANDA PORCH DECK OR BALCONY 12 INCHES 30cm...

Page 9: ...9 INCORRECT INCORRECT CORRECT Figure 14 Figure 15 Figure 16...

Page 10: ...IMITED IN DURATION TO THE PERIOD FOR WHICH EACH LIMITED WARRANTY IS GIVEN SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THE E...

Page 11: ...fourni LIMITATION DES GARANTIES TOUTE GARANTIE IMPLICITE Y COMPRIS TOUTE GARANTIE IMPLICITE DE QUALIT MARCHANDE SONT LIMIT ES LA DUR E DE LA P RIODE POUR LAQUELLE CHAQUE GARANTIE LIMIT E CERTAINS TAT...

Page 12: ...NAL M CLEARANCE UNDER VERANDA PORCH DECK OR BALCONY 12 INCHES 30cm E CLEARANCE TO UNVENTILATED SOFFIT F CLEARANCE TO OUTSIDE CORNER G CLEARANCE TO INSIDE CORNER H CLEARANCE TO EACH SIDE OF CENTER LINE...

Page 13: ...U ORANGE TYPE BIEN DEFINI CORRECT INEXACT Figure 11 LA TIGE DE L ANODE ANODE NEUVE ANODE CORROD E 75 Figure 12 8 LE BOUTON DE R ENCLENCHEMENT 120 V C A T STAT HAUTE LIMITE Figure 10 LE BOUTON DE 12 V...

Page 14: ...fermer le robinet et ouvrir l arriv e d eau froide La poche d air se forme R p ter cette op ration ces coulements d eau persistent on peut envisager d installer un r servoir de dilatation ou d accumu...

Page 15: ...t un pais s diment au bas du r servoir Si la tuyauterie n est pas quip d un conduit de d rivation et vous avez l intention de pr parer votre chauffe eau pour l hiver en y ajoutant un antigel enlevez l...

Page 16: ...ne pourrez pas parler avec votre fournisseur de gaz t l phoner le service des incendies C C est un tube gaz automatique les r glages ne sont pas n cessaires Ne pas tenter de r parer le tube gaz a peu...

Page 17: ...de toute surtension continue ou CA Nous recommandons l utilisation de bornes isol es pour toutes les connections lectriques LES BRANCHEMENTS LECTRIQUES 120 VOLTS C A A Se r f rer la Figure 2 pour l e...

Page 18: ...ENCADREE LE DETAIL A LA VIS SPECIALE LE BOITIER DE CONTROLE LA JOINT LE LOQUET LE BOITIER DE CONTROLE LA PORTE ENCASTREE CALFATER AUTOUR L OUVERTURE ENCADREE VOIR LA FIGURE NO 1 LA PEAU DE LA VOITURE...

Page 19: ...t appareil de fa on l vent se termine en dessous d un slide out Cet appareil ne doit pas tre install sous toute surplomb Il doit tre libre de toute masse en surplomb de type Cette installation doit co...

Page 20: ...OTRE S CURIT NE PAS EMMAGASINER OU UTILISER L ESSENCE OU LES AUTRES MATI RES COMBUSTIBLES OU LES LIQUIDES PR S OU ADJACENT CET CHAUFFE EAU OU AUCUN AUTRE APPAREIL CET APPAREIL NE DEVRA PAS TRE INSTALL...

Reviews: