Place the assembled Log Set (EC and ED) and Ember Bed (EG)  into 
the back of the unit behind the Glass Panel (L).

Push the tabs beneath the Log Set (EC and ED) and Ember Bed 
(EG)  into the holes on the Base (A).

Once the log set is in place, secure with Screws (BB) through the 
bottom of the Log Set (EC and ED) and Ember Bed (EG) and into 
the Base (A).

Assembling the fireplace

Securing the log set

Route the wires of the Log Set Left (EC) and the Log Set 
Right (ED) down the back of the Ember Bed (EG) and into 
the receiving tabs to secure in place. Refer to the lower 
diagram.

Gently plug the cords from both the Log Set Left (EC) and 
the Log Set Right (ED) into the ports as shown. Ensure the 
cords are plugged in straight.

Assembling the log set

Assembly (continued)

ED

ED

ED

A

EC

EG

A

EC

EC

EG

EG

Summary of Contents for WHEATON 1007519970/320010627/611768149018/23WM90536-PC78

Page 1: ...e our full line of products available for your home improvement needs Thank you for choosing StyleWell Questions problems missing parts Before returning to the store call Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 877 527 0313 HOMEDEPOT COM 1007519970 320010627 611768149018 23WM90536 PC78 319988351 611768150427 23WM90536 PB01 319988496 611768150434 23WM90536 PT01 319...

Page 2: ... maximum weights indicated may result in instability causing possible injury Maximum Load Warning 2 Safety Information 3 Warranty 5 Pre Assembly 6 Hardware Included 6 Product Specifications 6 Tools Required 6 Package Contents 7 Assembly 8 Operation 17 FCC IC Information 20 Care and Cleaning 20 Troubleshooting 21 Replacement Parts 23 Maximum Load Warning Table of Contents ...

Page 3: ...e Safety Information WARNING Under no circumstances should this fireplace be modified Parts that must be removed for servicing must be replaced prior to operating this fireplace again DANGER High temperatures may be generated under certain abnormal conditions Do not partially or fully cover or obstruct the front of this heater WARNING If the supply cord is damaged it must be replaced by the manufa...

Page 4: ...r cord until the missing or damaged part is correctly replaced To avoid electric shock use only identical replacement parts when servicing double insulated tools NOTE Use care in assembling your new fireplace Take your time and use the hardware provided and a quality Phillips head screwdriver Never overtighten bolts Do not sit on any part of the mantel It is recommended to work on a soft surface li...

Page 5: ...efective part s 5 Any installation labor construction transportation or other related costs expenses arising from defective part s repair replacement or otherwise of same will not be covered by this warranty nor shall the manufacturer assume responsibility for same 6 The owner user assumes all other risks if any including the risk of any direct indirect or consequential loss or damage arising out ...

Page 6: ...tached PH GLDBRW001 4 LL Metal Plate Pre attached PH PLTBRZ001 4 Pre Assembly HARDWARE INCLUDED CC DD EE FF GG HH II JJ KK LL AA BB NOTE Hardware not shown to actual size Phillips Screwdriver PRODUCT SPECIFICATIONS VOLTAGE 120VAC 60 Hz AMPS 12 5 Amps WATTS 1500 Watts PLANNING ASSEMBLY Before beginning assembly of product make sure all parts are present Compare parts with Hardware Included and Pack...

Page 7: ...ase Front Rail 1 I Base Back Rail 1 J Left side Partition 1 K Right side Partition 1 L Glass Panel 1 M Electric Fireplace Back Panel 1 EA Front Panel with Control Button 1 EB Heater Box 1 EC Log Set Left 1 ED Log Set Right 1 EF Bracket 0110 2 EG Ember Bed 1 EH Remote 1 PACKAGE CONTENTS NOTE All panels are labeled left and right as viewed from the front of unit Pre Assembly continued C EB EF EF EA ...

Page 8: ...the left and right surround panels to the upper front panel 3 Locate the Front Panel with Control Button EA Using Screws BB secure the Front Panel with Control Button EA between the Left and Right Surround Panels D and E and just below the Upper Front Panel F as shown Attaching the fireplace front plate 1 Insert the Wire Clip JJ into the pre drilled holes in the Right Surround Panel E pushing them...

Page 9: ...he electric fireplace glass front L 5 Locate the Base Front Rail H Place the Base Front Rail H on a flat surface and insert four Cam Bolts CC as shown Preparing base for assembly H CC 6 Align the pre drilled holes of the assembled surround panels from step 2 E F D with the Cam Lock DD on the edge of the Base Front Rail H Secure the Base Front Rail H to the surround panel assembly D E F with the Ca...

Page 10: ...oles on Bottom Shelf A Secure the Base Back Rail I in place by tightening the fasteners with a Phillips screwdriver as shown Attaching the sides to the base Attaching the base back rail 9 Attach the front assembly to the sides by aligning the pre installed hardware on the edges of the side and bottom assembly with the pre drilled holes on front assembly Secure the side and bottom assembly to the f...

Page 11: ...partitions J and K with the pre drilled holes Secure the Left and Right Side Partitions to the front assembly by tightening the fasteners with a Phillips screwdriver as shown Insert the Cam Locks DD over the Cam Bolt CC Tighten with a Phillips screwdriver to tighten the cam locks and secure the base Attaching the left and right side partitions Securing the base J K fastener ...

Page 12: ...aring the top panel Assembly continued G G CC DD 13 Align the pre installed hardware on the edges of the main assembly with the pre drilled holes in the Top Panel G Secure the Top Panel to the front assembly by tightening the fasteners with a Phillips screwdriver as shown Attaching the top panel fastener ...

Page 13: ...J EB ED EC EG 15 16 14 Secure the Heater Box EB in place by screwing Screws FF through the holes in the Brackets EF and into pre drilled holes in the Left and Right side partitions J and K from Step 11 Place the Log Set Left EC into the Ember Bed EG as shown Repeat with the Log Set Right ED Installing the fireplace heater Assembling the log set Attaching the insert brackets Assembly continued ...

Page 14: ... Log Set EC and ED and Ember Bed EG and into the Base A Assembling the fireplace Securing the log set Route the wires of the Log Set Left EC and the Log Set Right ED down the back of the Ember Bed EG and into the receiving tabs to secure in place Refer to the lower diagram Gently plug the cords from both the Log Set Left EC and the Log Set Right ED into the ports as shown Ensure the cords are plug...

Page 15: ...zable look Place the Back Panel Brackets HH between the Fireplace Back Panel M and the grooves of the assembly as shown Fasten each Back Panel Bracket HH using Screws GG Repeat until all brackets are in place as indicated by the diagram Placing the fireplace background Securing the fireplace background Connect Key Button Connection Wire to heater Insert the Ember Bed Connection Wire into the heate...

Page 16: ...the Wall Anchor and Unit Anchor Reattach the loose cable to the connector but do not tighten Locate a secure wall stud behind the unit closest to the right side and repeat the steps above Tighten both Anchor Tethers by pulling the cable through the connector Installing the tipping restraint hardware WARNING Installing the Tipping Restraint Hardware will help prevent accidents or damage to the unit...

Page 17: ...nsert in a standby mode Push the Power button again to turn off all functions 1 2 Powering the fireplace NOTE Holding the Power button on the control panel for 10 seconds will disable the heater function NOTE All previous settings are held in memory so the next time you power up the fireplace the unit will turn on with the same settings Adjusting the flame There are 5 brightness levels that can be...

Page 18: ...inside the battery compartment Replace the battery compartment door 6 Replacing the remote control battery NOTE Batteries should be removed if the product is to be left unused for a long time The battery may contain hazardous substances that could endanger the environment and human health This symbol marked on the battery and or packaging indicates that used battery should not be treated as munici...

Page 19: ...et overheating If the Safer Plug cuts the power due to unsafe conditions it will show an Er message on the screen If this occurs the Safer Plug has prevented a potentially unsafe condition To reset the device if this occurs first allow the plug to cool down Once the plug has cooled down unplug the device and wait 5 seconds then plug back in and continue to use normally If the Safer Plug continues ...

Page 20: ...nto an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undes...

Page 21: ...ctions or loose plugs can cause the outlet or plug to overheat Be sure the plug fits tight in the outlet Heaters draw more current than small appliances Overheating of the outlet may occur even if it has not occurred with the use of other appliances During use check frequently to determine if your plug outlet or faceplate is HOT If so discontinue use of the heater and have a qualified electrician ...

Page 22: ...mitter at a slow measured pace Press the remote control buttons with an even motion and gentle pressure Repeat edly pressing buttons in rapid succession may cause the transmitter to malfunction The remote is too far from the heater Operate the remote at a distance less than 20 ft from the front of the appliance point the remote at the control panel Troubleshooting ...

Page 23: ...on Qty PART NUMBER 1 Thermostat Sensor 1 Y21 S307 P186 2 Blower HeaterAssembly 1 Y21 S307 P01 3 Main Circuit Board 1 Y21 S307 P15 4 Key Button Connection Wire 1 Y21 S307 P187 5 Ember Bed Connection Wire 1 Y21 S307 P188 6 Flame Generator Drive Motor 1 Y21 S307 P189 7 Flame Circuit Board 1 Y21 S307 P40 8 Control Panel Circuit Board 1 Y21 S307 P32 9 Remote Control 1 P185HD 10 Logset left 1 Y21 S307 P...

Page 24: ...24 Notes ...

Page 25: ...ions problems missing parts Before returning to the store call StyleWell Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 877 527 0313 HOMEDEPOT COM Retain this manual for future use ...

Reviews: