background image

Sturtevant Richmont

 -  P/N 857285 - Issue Date 100407 - Page 5 of 14

Red Light 

Color projected onto display to indicate that the current torque exceeds the maximum 
torque specified for that Task. Use of the LED color scheme is selectable in the software 
(active or inactive). Active in all Tasks numbered greater than “00”. Not available in “Task 
00” or Record “00”.

Keypad

The keypad to the right of the display has four buttons: Clear, Select, Up and Down.

Clear 

The Clear button is used to clear a reading from the tool and make that Task/Record combination 
the active combination for the next torque application. Example: The operator makes an error in 
tightening the fastener. The operator returns to the correct record within the task for that record, 
then presses the Clear button. This clears the display of the reading and displays the target 
torque, as though the operator were facing that fastener for the fi rst time. The operator may then 
properly tighten the fastener and store the torque value for the retorque where the original value 
was stored.

Select 

The Select button is used to navigate among tasks. During normal (job loaded) operation, press 
the select button once to permit navigation among the tasks currently on the tool. Use the Up and 
Down buttons to navigate to the task to be performed. Press the Select button again to make that 
task the active task. Note that when so doing it is necessary to use the Up and Down buttons to 
navigate to the record of interest after the task has been selected.

Up 

Navigate among tasks and records. Increments count of displayed task or record by one.

Down 

Navigate among tasks and records. Decrements count of displayed task or record by one.

Display During Operation
Exacta® Plus 

uses a liquid crystal display and a buzzer to communicate. The display content is grouped 

into four categories: items displayed during startup when the power is turned on, items displayed during 
PC communications, items displayed during normal operation, and items displayed when results are being 
reviewed.

Items Displayed During Startup
1. 

The tool series number “3000” will be displayed in the center, and “r00N” in the Task and Record 
markings will be displayed for 1 - 2 seconds. “N” is the firmware revision number.

2. 

The tool capacity will be displayed in the center for 1 - 2 seconds.

3. 

Upon completion of the startup routine, what is displayed is dependent upon whether or not there 
are tasks in the memory of the tool

 

 

If no Tasks are in memory, the following will appear on the display:

 

 

 

Indicator for the Peak mode will be lit.

 

 

 

Indicator for Target will be lit.

 

 

 

IN.LB Unit Of Measure will be lit.

 

 

 

-000.0 will be displayed as the current torque value.

 

 

 

00 will be displayed for the Task number.

 

 

 

00 will be displayed for the Record number.

 

 

If one or more Tasks are in tool memory, the following will appear on the display:

 

 

 

Indicator for the active mode will be lit.

 

 

 

The indicator for the active Unit Of Measure will be lit.

 

 

 

The Target torque will be the displayed torque value.

 

 

 

The number of tasks in memory will be displayed in the Task section.

 

After startup the last task and record number worked on will be displayed. If the tool memory has 
been cleared, the task and record will each be “00”.

Summary of Contents for exacta 2 3000 series

Page 1: ...nd Battery Chargers These tools were designed to use only and solely NiMH batteries having specific dimensions and operating characteristics Within NAFTA countries the only batteries that are to be us...

Page 2: ...At that time the display will show the message bAtt and the ability to operate the wrench will be lost Readings stored prior to that point will remain in memory The tool will remain inoperable until...

Page 3: ...tion here due to differences in the fonts used Target When the triangular icon beneath this is illuminated it means that the target value for the torque specification is displayed in the main section...

Page 4: ...specific Task Numbered from 00 to 50 Record 00 is designed to give the user the ability to use the specifications for the active task on a fastener without recording the result UOM Currently active Un...

Page 5: ...ted Up Navigate among tasks and records Increments count of displayed task or record by one Down Navigate among tasks and records Decrements count of displayed task or record by one Display During Ope...

Page 6: ...the Exacta Plus software is being used to communicate with it avoid touching the buttons on the tool and do not disable the power Allow the software to perform the communications and complete them bef...

Page 7: ...records for that task have been obtained Once the last fastener in a task has been completed the information will be displayed normally then the screen will display SEt in the main section Use the Up...

Page 8: ...but the use of a mechanical loader is still recommended The load applied during testing must be at the loading point on the grip indicated by the plain ring at the middle of the grip It is imperative...

Page 9: ...diagnostic D Command into the terminal and press enter The Terminal display will dis play DiaOn You are now in diagnostic mode 8 Type the M enter The capacity of the tool should be seen on the displa...

Page 10: ...ress the DOWN arrow key Unload the tool 6 Press the Up arrow key until 70 appears in the lower right corner of the LCD display Apply 70 CW FS load to the unit When exactly 70 CW FS torque is applied p...

Page 11: ...load to the unit When exactly 60 CCW FS torque is applied press the DOWN arrow key Unload the tool 20 Press the Up arrow key until 50 appears in the lower right corner of the LCD display Apply 50 CCW...

Page 12: ...300 303 297 75 foot pounds Capacity in Ft Lb FS Torque Value in In Lb Tol Tol 75 10 90 90 9 89 1 20 180 181 8 178 2 30 270 272 7 267 3 40 360 363 6 356 4 50 450 454 5 445 5 60 540 545 4 534 6 70 630...

Page 13: ...4 30 1440 1454 4 1425 6 40 1920 1939 2 1900 8 50 2400 2424 2376 60 2880 2908 8 2851 2 70 3360 3393 6 3326 4 80 3840 3878 4 3801 6 90 4320 4363 2 4276 8 100 4800 4848 4752 600 foot pounds Capacity in F...

Page 14: ...to the sensor including damage of a level that necessitates replacement We strongly recommend that the tool never be used beyond its rated capacity and that if the tool is inadvertently overloaded it...