PAGE 1 OF 8
0514 IH-3535
π
H-3535
KiHlberg JK35-590
Wide CroWn
PneumatiC taCKer
1-800-295-5510
uline.com
OPERATION
lOAdINg ThE mAgAzINE
1. Pull the pusher all the way back until it snaps in
around the parking button. Feed in a staple strip
from above into the magazine and push it forward
by hand. (See Figure 1)
2. Release the pusher by pressing the parking button.
(See Figure 2)
USINg ThE STAPlER
WARNINg! Be sure that the stapler nozzle is
not pointed at yourself or anyone else when
connecting it to the compressed air line.
1. Adjust the air pressure to the lowest one that
will drive staples to the desired depth. Start at
approximately 5.5 bar and raise this by 0.5 bar
increments until the correct operating pressure for
the job is found.
CAUTION! Never exceed 7 bar air pressure. A
low air pressure will reduce maintenance costs!
2. Place the stapler firmly on the work surface. Never
drive staples into extremely hard or brittle material.
Do not drive staples at too steep an angle or too
close to the edge of the work; the staple might fly
free and cause injury.
3. This stapler has only single shot firing with safety yoke.
a. First place the stapler against the work piece.
b. Then pull the trigger. (See Figure 3)
4. As this stapler is equipped with a safety yoke, it can
also be bump fired where there is no great need for
stapling precision.
Figure 2
A
B
Figure 3
Pusher
Parking
Button
Figure 1
Pour le français, consulter les pages 5-8.