background image

Sturtevant Richmont

 -  P/N 857285 - Issue Date 100407 - Page 7 of 14

•  To navigate to the desired task, press the Select button one time. The word “SEt” will appear in the main 

section of the display. The task number of the last task downloaded will be in the Task section display.

•  Use the down arrow to scroll through the task numbers until the desired task number appears.

•  Press the SEt button a second time to make that the active task. The display will show the unit of 

measure, mode and target value for this task.

•  The record number will be “00”. To change the record, press the Up button one time to go to the “01” 

record. Once this is displayed, the tool can be used and recording will start at the fi rst record.

As you start applying torque to the fi rst fastener, the main section of the display will change from the target 
torque to the current torque value. When you reach the Warning Torque for the task, an LED will backlight 
the screen and light the lens with a yellow-orange light to alert you that you are approaching the specifi ed 
torque. When the minimum torque specifi cation is achieved, the illumination will change from yellow-orange 
to bright green, and the beeper will emit fi ve rapid pulses.

Stop the force application and remove the tool from the fastener. The torque for that fastener and the task 
and record number for it will remain on the screen for three seconds. The tool will then turn off the LED 
and index to the next fastener in the task (if more than one). This inform/warn/record/inform/index cycle will 
repeat until all of the fastening records for that task have been obtained.

Once the last fastener in a task has been completed, the information will be displayed normally, then the 
screen will display “SEt” in the main section.

Use the Up arrow key to go to the next task in the sequence. When the desired task is displayed, press the 
Select button again to make this the active task. The tool will be in the “00” record; press the Up button to 
go to the fi rst fastener in the task.

At any time when the tool is not applying torque you can leave the current task and move to a different task 
by using the Select button. At the new task you can use the tool in the “00” mode or you can select the 
fastener(s) in the task to be tightened and use the tool normally.

Correcting an Error

If you make an error in a torque application and wish to correct it and the record for that fastener, this can 
be achieved easily. There is a slightly different method to be used if the torque was too low than if it was 
too high.

If the torque was too low:
1.  Use the Select, Up and Down buttons to navigate to the applicable task and record.
2.  When the correct record is displayed, press the Clear button.
3.  Use the tool to apply the correct torque. This will store the new data where the old data was. You can 

then navigate to the next task and record to be worked on.

If the torque was too high:
1.  Use the Select, Up and Down buttons to navigate to the “00” record for that task.
2.  Loosen the overtorqued item.
3.  Use the Select, Up and Down buttons to navigate to the applicable task and record.
4.  When the correct record is displayed, press the Clear button.
5.  Use the tool to apply the correct torque. This will store the new data where the old data was. You can 

then navigate to the next task and record to be worked on.

Summary of Contents for exacta 2 3000 series

Page 1: ...nd Battery Chargers These tools were designed to use only and solely NiMH batteries having specific dimensions and operating characteristics Within NAFTA countries the only batteries that are to be us...

Page 2: ...At that time the display will show the message bAtt and the ability to operate the wrench will be lost Readings stored prior to that point will remain in memory The tool will remain inoperable until...

Page 3: ...tion here due to differences in the fonts used Target When the triangular icon beneath this is illuminated it means that the target value for the torque specification is displayed in the main section...

Page 4: ...specific Task Numbered from 00 to 50 Record 00 is designed to give the user the ability to use the specifications for the active task on a fastener without recording the result UOM Currently active Un...

Page 5: ...ted Up Navigate among tasks and records Increments count of displayed task or record by one Down Navigate among tasks and records Decrements count of displayed task or record by one Display During Ope...

Page 6: ...the Exacta Plus software is being used to communicate with it avoid touching the buttons on the tool and do not disable the power Allow the software to perform the communications and complete them bef...

Page 7: ...records for that task have been obtained Once the last fastener in a task has been completed the information will be displayed normally then the screen will display SEt in the main section Use the Up...

Page 8: ...but the use of a mechanical loader is still recommended The load applied during testing must be at the loading point on the grip indicated by the plain ring at the middle of the grip It is imperative...

Page 9: ...diagnostic D Command into the terminal and press enter The Terminal display will dis play DiaOn You are now in diagnostic mode 8 Type the M enter The capacity of the tool should be seen on the displa...

Page 10: ...ress the DOWN arrow key Unload the tool 6 Press the Up arrow key until 70 appears in the lower right corner of the LCD display Apply 70 CW FS load to the unit When exactly 70 CW FS torque is applied p...

Page 11: ...load to the unit When exactly 60 CCW FS torque is applied press the DOWN arrow key Unload the tool 20 Press the Up arrow key until 50 appears in the lower right corner of the LCD display Apply 50 CCW...

Page 12: ...300 303 297 75 foot pounds Capacity in Ft Lb FS Torque Value in In Lb Tol Tol 75 10 90 90 9 89 1 20 180 181 8 178 2 30 270 272 7 267 3 40 360 363 6 356 4 50 450 454 5 445 5 60 540 545 4 534 6 70 630...

Page 13: ...4 30 1440 1454 4 1425 6 40 1920 1939 2 1900 8 50 2400 2424 2376 60 2880 2908 8 2851 2 70 3360 3393 6 3326 4 80 3840 3878 4 3801 6 90 4320 4363 2 4276 8 100 4800 4848 4752 600 foot pounds Capacity in F...

Page 14: ...to the sensor including damage of a level that necessitates replacement We strongly recommend that the tool never be used beyond its rated capacity and that if the tool is inadvertently overloaded it...