background image

Sturtevant Richmont

 -  P/N 857285 - Issue Date 100407 - Page 3 of 14

Power Switch, Serial Port and Cover

On the top of the electronics housing are the power switch and serial port for the tool. These are protected 
by a rubber that can be lifted to expose them for use. The cover should be closed at all times when access 
to the serial port and/or power switch is not immediately 
needed.

The tool power is enabled (power On) by sliding the switch 
away from the grip as shown here. Power to the tool is 
disabled (power Off) by sliding the power switch towards the 
grip.

The serial cable for the wrench connects to the round serial 
port that is also used to hold the cover in place. The cable 
should fi rst be connected to the computer (9-pin connector) 
then to the tool (single-pin connector) when the tool is to communicate with the computer and software.

Display Elements

Text Indicators and Triangular Icons
There are four words of text above the LCD. Each of the words: Target, Residual, Peak, and Stored has a 
triangular icon underneath it along the top of the LCD. The icons are used in conjunction with the values in 
other areas of the display. Note: The display will vary slightly from the depiction here due to differences in 
the fonts used.

Target

When the triangular icon beneath this is illuminated, it means that the target value for the torque 
specifi cation is displayed in the main section of the display. The target 
value is the midpoint between the minimum and maximum torque 
specifi cation values.

Residual

When the triangular icon beneath this is illuminated, it means that the 
Residual mode is the current torque measurement mode.

Peak

When the triangular icon beneath this is illuminated, it means that the Peak mode is the current torque 
measurement mode.

Record

When the triangular icon beneath this is illuminated, it means that the specifi c record in the lower right-
hand corner of the display is being reviewed and the torque for that record is the torque value currently 
displayed.

Unit of Measure Indicator
Available units of measure include inch-pounds, foot-pounds and Newton metres. The current unit of mea-
sure is displayed to the right of the main section of the display.

Main Section
The main section of the display is used to display a variety of information important to the current function-
ing of the tool. During normal use, the target torque or the current torque will be displayed, depending upon 
whether the tool is awaiting use or actually tightening a fastener. The triangular icons and text along the top 
indicate which value is being displayed. 

Summary of Contents for exacta 2 3000 series

Page 1: ...nd Battery Chargers These tools were designed to use only and solely NiMH batteries having specific dimensions and operating characteristics Within NAFTA countries the only batteries that are to be us...

Page 2: ...At that time the display will show the message bAtt and the ability to operate the wrench will be lost Readings stored prior to that point will remain in memory The tool will remain inoperable until...

Page 3: ...tion here due to differences in the fonts used Target When the triangular icon beneath this is illuminated it means that the target value for the torque specification is displayed in the main section...

Page 4: ...specific Task Numbered from 00 to 50 Record 00 is designed to give the user the ability to use the specifications for the active task on a fastener without recording the result UOM Currently active Un...

Page 5: ...ted Up Navigate among tasks and records Increments count of displayed task or record by one Down Navigate among tasks and records Decrements count of displayed task or record by one Display During Ope...

Page 6: ...the Exacta Plus software is being used to communicate with it avoid touching the buttons on the tool and do not disable the power Allow the software to perform the communications and complete them bef...

Page 7: ...records for that task have been obtained Once the last fastener in a task has been completed the information will be displayed normally then the screen will display SEt in the main section Use the Up...

Page 8: ...but the use of a mechanical loader is still recommended The load applied during testing must be at the loading point on the grip indicated by the plain ring at the middle of the grip It is imperative...

Page 9: ...diagnostic D Command into the terminal and press enter The Terminal display will dis play DiaOn You are now in diagnostic mode 8 Type the M enter The capacity of the tool should be seen on the displa...

Page 10: ...ress the DOWN arrow key Unload the tool 6 Press the Up arrow key until 70 appears in the lower right corner of the LCD display Apply 70 CW FS load to the unit When exactly 70 CW FS torque is applied p...

Page 11: ...load to the unit When exactly 60 CCW FS torque is applied press the DOWN arrow key Unload the tool 20 Press the Up arrow key until 50 appears in the lower right corner of the LCD display Apply 50 CCW...

Page 12: ...300 303 297 75 foot pounds Capacity in Ft Lb FS Torque Value in In Lb Tol Tol 75 10 90 90 9 89 1 20 180 181 8 178 2 30 270 272 7 267 3 40 360 363 6 356 4 50 450 454 5 445 5 60 540 545 4 534 6 70 630...

Page 13: ...4 30 1440 1454 4 1425 6 40 1920 1939 2 1900 8 50 2400 2424 2376 60 2880 2908 8 2851 2 70 3360 3393 6 3326 4 80 3840 3878 4 3801 6 90 4320 4363 2 4276 8 100 4800 4848 4752 600 foot pounds Capacity in F...

Page 14: ...to the sensor including damage of a level that necessitates replacement We strongly recommend that the tool never be used beyond its rated capacity and that if the tool is inadvertently overloaded it...

Reviews: