background image

Sturtevant Richmont

 -  P/N 857285 - Issue Date 100407 - Page 2 of 14

Battery Installation

At the end of the grip is a battery cap that covers the battery compartment inside the grip. To install the 
batteries:

1.  Insure that the correct batteries are those to be used, and 

that they are completely charged. Follow the instructions 
that come with the charger to charge the batteries before 
installing them.

2.  The battery cap is screwed into an internal thread inside 

the grip. Remove the battery cap by unscrewing it from 
the grip (CCW).

3.  The battery compartment will be exposed. There are two 

labels inside the compartment. Install the batteries in the 
locations given by the labels and maintaining the battery 
orientation shown by the labels and in the photo here.

4.  Reinstall the battery cap. Tighten the cap only to snug; do 

not overtighten the cap.

The 3000-Series 

Exacta

®

 

2

 has a Low Battery Indicator on 

the display.  If the battery voltage falls below 4.1 volts, a 
battery icon will appear in the upper right-hand section of the 
display, the “BAD” icon will illuminate and “bAtt” will be displayed in the main display.  When this occurs it 
is time to replace the batteries.  Wrench will continue to operate until the battery voltage drops below 4.0 
volts. At that time the display will show the message “bAtt” and the ability to operate the wrench will be 
lost. Readings stored prior to that point will remain in memory. The tool will remain inoperable until the 
batteries have been replaced with charged batteries.

Interchangeable Heads

The 3000-Series 

Exacta

®

 2

 digital torque wrenches of 150 foot-pound capacity and below use the S/R 

dovetail system. The tools are calibrated for use with S/R Interchangeable Heads having a 1 

7

/

16

” Common 

Centerline. Any S/R heads with this centerline length may be used without affecting torque accuracy. If an 
interchangeable head of a different centerline length is to be used, the tool must be recalibrated with that 
head (or one of the same centerline length) before the tool is used.

The 400 foot-pound capacity tool is calibrated for interchangeable heads having a Common Centerline 
length of 3 

7

/

8

”. When used with heads having the same Common Centerline length, no recalibration is 

needed. If a head with a different Common Centerline length is to be used, the tool must be recalibrated 
before use with an interchangeable head of the same Common Centerline length as the one to be used.

3000-Series 

Exacta

®

 2

 digital torque wrenches of 250 foot-pound capacity and above (except 400 ft. lb.) 

use S/R slide pin ratchets. The ratchets should be disassembled and cleaned periodically. Ratchet renewal 
kits having the appropriate parts for each ratchet are available.

Summary of Contents for exacta 2 3000 series

Page 1: ...nd Battery Chargers These tools were designed to use only and solely NiMH batteries having specific dimensions and operating characteristics Within NAFTA countries the only batteries that are to be us...

Page 2: ...At that time the display will show the message bAtt and the ability to operate the wrench will be lost Readings stored prior to that point will remain in memory The tool will remain inoperable until...

Page 3: ...tion here due to differences in the fonts used Target When the triangular icon beneath this is illuminated it means that the target value for the torque specification is displayed in the main section...

Page 4: ...specific Task Numbered from 00 to 50 Record 00 is designed to give the user the ability to use the specifications for the active task on a fastener without recording the result UOM Currently active Un...

Page 5: ...ted Up Navigate among tasks and records Increments count of displayed task or record by one Down Navigate among tasks and records Decrements count of displayed task or record by one Display During Ope...

Page 6: ...the Exacta Plus software is being used to communicate with it avoid touching the buttons on the tool and do not disable the power Allow the software to perform the communications and complete them bef...

Page 7: ...records for that task have been obtained Once the last fastener in a task has been completed the information will be displayed normally then the screen will display SEt in the main section Use the Up...

Page 8: ...but the use of a mechanical loader is still recommended The load applied during testing must be at the loading point on the grip indicated by the plain ring at the middle of the grip It is imperative...

Page 9: ...diagnostic D Command into the terminal and press enter The Terminal display will dis play DiaOn You are now in diagnostic mode 8 Type the M enter The capacity of the tool should be seen on the displa...

Page 10: ...ress the DOWN arrow key Unload the tool 6 Press the Up arrow key until 70 appears in the lower right corner of the LCD display Apply 70 CW FS load to the unit When exactly 70 CW FS torque is applied p...

Page 11: ...load to the unit When exactly 60 CCW FS torque is applied press the DOWN arrow key Unload the tool 20 Press the Up arrow key until 50 appears in the lower right corner of the LCD display Apply 50 CCW...

Page 12: ...300 303 297 75 foot pounds Capacity in Ft Lb FS Torque Value in In Lb Tol Tol 75 10 90 90 9 89 1 20 180 181 8 178 2 30 270 272 7 267 3 40 360 363 6 356 4 50 450 454 5 445 5 60 540 545 4 534 6 70 630...

Page 13: ...4 30 1440 1454 4 1425 6 40 1920 1939 2 1900 8 50 2400 2424 2376 60 2880 2908 8 2851 2 70 3360 3393 6 3326 4 80 3840 3878 4 3801 6 90 4320 4363 2 4276 8 100 4800 4848 4752 600 foot pounds Capacity in F...

Page 14: ...to the sensor including damage of a level that necessitates replacement We strongly recommend that the tool never be used beyond its rated capacity and that if the tool is inadvertently overloaded it...

Reviews: