250 foot-pounds

Capacity in 

 Ft.Lb

% FS

Torque Value in

 In.Lb

+ Tol.

-Tol.

250

10

300

303

297

20

600

606

594

30

900

909

891

40

1200

1212

1188

50

1500

1515

1485

60

1800

1818

1782

70

2100

2121

2079

80

2400

2424

2376

90

2700

2727

2673

100

3000

3030

2970

400 foot-pounds

Capacity in 

 Ft.Lb

% FS

Torque Value in

 In.Lb

+ Tol.

-Tol.

400

10

480

484.8

475.2

20

960

969.6

950.4

30

1440

1454.4

1425.6

40

1920

1939.2

1900.8

50

2400

2424

2376

60

2880

2908.8

2851.2

70

3360

3393.6

3326.4

80

3840

3878.4

3801.6

90

4320

4363.2

4276.8

100

4800

4848

4752

600 foot-pounds

Capacity in 

 Ft.Lb

% FS

Torque Value in

 In.Lb

+ Tol.

-Tol.

600

10

720

727.2

712.8

20

1440

1454.4

1425.6

30

2160

2181.6

2138.4

40

2880

2908.8

2851.2

50

3600

3636

3564

60

4320

4363.2

4276.8

70

5040

5090.4

4989.6

80

5760

5817.6

5702.4

90

6480

6544.8

6415.2

100

7200

7272

7128

Parts and Repair

Original parts and factory repair services are available when needed. Simply contact us using the informa-
tion on the fi rst page of this document.

Summary of Contents for exacta 2 3000 series

Page 1: ...nd Battery Chargers These tools were designed to use only and solely NiMH batteries having specific dimensions and operating characteristics Within NAFTA countries the only batteries that are to be us...

Page 2: ...At that time the display will show the message bAtt and the ability to operate the wrench will be lost Readings stored prior to that point will remain in memory The tool will remain inoperable until...

Page 3: ...tion here due to differences in the fonts used Target When the triangular icon beneath this is illuminated it means that the target value for the torque specification is displayed in the main section...

Page 4: ...specific Task Numbered from 00 to 50 Record 00 is designed to give the user the ability to use the specifications for the active task on a fastener without recording the result UOM Currently active Un...

Page 5: ...ted Up Navigate among tasks and records Increments count of displayed task or record by one Down Navigate among tasks and records Decrements count of displayed task or record by one Display During Ope...

Page 6: ...the Exacta Plus software is being used to communicate with it avoid touching the buttons on the tool and do not disable the power Allow the software to perform the communications and complete them bef...

Page 7: ...records for that task have been obtained Once the last fastener in a task has been completed the information will be displayed normally then the screen will display SEt in the main section Use the Up...

Page 8: ...but the use of a mechanical loader is still recommended The load applied during testing must be at the loading point on the grip indicated by the plain ring at the middle of the grip It is imperative...

Page 9: ...diagnostic D Command into the terminal and press enter The Terminal display will dis play DiaOn You are now in diagnostic mode 8 Type the M enter The capacity of the tool should be seen on the displa...

Page 10: ...ress the DOWN arrow key Unload the tool 6 Press the Up arrow key until 70 appears in the lower right corner of the LCD display Apply 70 CW FS load to the unit When exactly 70 CW FS torque is applied p...

Page 11: ...load to the unit When exactly 60 CCW FS torque is applied press the DOWN arrow key Unload the tool 20 Press the Up arrow key until 50 appears in the lower right corner of the LCD display Apply 50 CCW...

Page 12: ...300 303 297 75 foot pounds Capacity in Ft Lb FS Torque Value in In Lb Tol Tol 75 10 90 90 9 89 1 20 180 181 8 178 2 30 270 272 7 267 3 40 360 363 6 356 4 50 450 454 5 445 5 60 540 545 4 534 6 70 630...

Page 13: ...4 30 1440 1454 4 1425 6 40 1920 1939 2 1900 8 50 2400 2424 2376 60 2880 2908 8 2851 2 70 3360 3393 6 3326 4 80 3840 3878 4 3801 6 90 4320 4363 2 4276 8 100 4800 4848 4752 600 foot pounds Capacity in F...

Page 14: ...to the sensor including damage of a level that necessitates replacement We strongly recommend that the tool never be used beyond its rated capacity and that if the tool is inadvertently overloaded it...

Reviews: