STUDIO DUE 0102 Manual Download Page 8

DRIVING THE MINICITY250 WITH A DMX 512 REMOTE CONTROLLER

• Select the requested DMX starting address by operating on the Addr option
• Select the requested number of channel with NChn option
• Connect the DMX signal between the fixture and the controller
• Check that the DMX led is flasing. (DMX signal present)
• If there is no signal, you must manually reset by operating on the RESET option

It is possible to choose a standard configuration occupying 6 DMX channels, or a  enanched configurationoccupying 7 channels.
Use the enanched configuration if you want to activate channel 7 which enables the reset of the motors and the switching off of
the lamp from the controller.

6/7 CHANNELS MODE SELECTION

Press the MENU button on the control panel up to when the option nChn is shown on the display, select it by pressing ENTER and
the set indication will appear (6 or 7 channels). If you want to activate channel 7 you must set 6 channels on the display. Pass
through the numbers by pressing the buttons UP and DOWN: once you have set the required number, store it by  pressing the
ENTER button and keep it pressed  up to when the display stops flashing (the flashing shows that the selected option is different
from the one previously stored). To exit from the selected option without making any change press the MENU button.

Here below is shown the complete list of the functions of the MiniCity250.
The complete list of the DMX values can be found in appendix “A”, page XI

7 CHANNELS

6 CHANNELS

CH 1=Speed

CH 1=Speed

CH 2=Cyan

CH 2=Cyan

CH 3=Yellow

CH 3=Yellow

CH 4=Magenta

CH 4=Magenta

CH 5=Dimmer

CH 5=Dimmer

CH 6=Beam angle

CH 6=Beam angle

CH 7=Reset/Lamp Off

... 7 ...

FOCU 

(Focus control)

To visualise the focus  position press ENTER.
Use Down and Up buttons to change the channel and, once the required one has been selected, press and keep ENTER pressed up to
when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). It is possible to set  0
to  255 step). To go back to the options without making any change, press the MENU button.

nChn

 (Number of Channel)

To visualise the number of channel press ENTER.
Use Down and Up buttons to change the channel and, once the required one has been selected, press and keep ENTER pressed up to
when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). It is possible to set 6
channels or 7 channels ( remote reset and remote lamp switch off ). To go back to the options without making any change, press the
MENU button.

teSt

 (

Autotest)

To insert the auto-test press ENTER and keep it pressed up to when the display shows the flashing message  t-on (test on). To take off
the auto-test  press the MENU button. To go back to the options without making any change, press the MENU button.

FLIP

 (Display overturning)

The display visualisation can be standard or overturned: by pressing the ENTER button the two modes will be alternatively visible. The
selected one will be immediately stored in the spot setting.
To go back to the options without making any change, press the MENU button.

rSEt

 (Reset)

To run the complete reset press ENTER and keep it pressed up to when the display shows the flashing message r-on (reset on).
Once the reset  procedure has been completed the spot will go back to the normal setting. To go back to the options without mak-
ing any change, press the MENU button.

Summary of Contents for 0102

Page 1: ...ing page 4 Control panel and configuration page 5 Use of the MiniCity250 page 7 DMX signal connection page 8 DMX line and terminator page 9 Automode functioning page 10 Troubleshooting page 11 System...

Page 2: ...ith the following lamp only Philips MSD 250 2 DO NOT USE ANY OTHER TYPE LAMP 2 Maintain minimum distance of 0 3 meter from walls or any other type flammable surfaces 3 Maintain minimum distance to lig...

Page 3: ...mode POWER SUPPLY Rated voltage 230V 50Hz 230V 60Hz on request 117Vac 60Hz 100Vac 50Hz Rated power 350W Rated current 1 7A 230V FUSES Lamp fuse 5 0A 250V delay time Electronic fuse 2 0A 250V delay tim...

Page 4: ...connection cable on the spot when it is warm 1b This unit must be positioned as to allow its ventilation Be careful not to acclude the in out ventilating grilles 1c The unit must be positioned at lea...

Page 5: ...cloth and alcohol 8 Install again the reflector parabole in the original position and screw the two screws A and B again 9 Install again in the correct position the glass cover 10 Check carefully the...

Page 6: ...remotely controlled off lamp switched on DIMMER led flashing the lamp is 33 dimmered off lamp switched on BUTTONS Four buttons are used to programme the spot MENU to select the programming options DOW...

Page 7: ...at the selected option is different from the pre set one The available op tions are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27 for the master functioning with the re specti...

Page 8: ...r CH 6 Beam angle CH 6 Beam angle CH 7 Reset Lamp Off 7 FOCU Focus control To visualise the focus position press ENTER Use Down and Up buttons to change the channel and once the required one has been...

Page 9: ...data transmission sect 2x0 25 gnd If the lines have a total length over 150 200 mts it is suggested to use a signal amplifier art 3004 DMX repeter amplifier The usage of a normal microphonic or audio...

Page 10: ...OGRAMMING SPOTS FUNCTIONS PROGRAMS SPOTS STEPS SELECT PLAY OUT IN DMX repeater amplifier L N L N 9 DMX TERMINAL LINE The wrong connection of the terminal line or its non connection are probably the mo...

Page 11: ...isplay stops flashing it flashes to indicate that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27...

Page 12: ...ted solutions The unit does not turn on the fans do not work The unit is completely dead Measure the mains voltage on the main connector If you have the right value the main fuses are blown No power P...

Page 13: ...the units are set in DMX mode After the configuration reset all the fixtures The controller is not connected to the fixtures The cable from the controller to the first of the MiniCity250 is interrupt...

Page 14: ...EPROTECTION MOT2 DIMMER MOT5 CYAN U12 7805 5V TOHEAD THERMAL SENSOR ANDSWITCH MAINPOWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER U10 MICRO PWM FAN CONTROLLER MOT3 MAGE...

Page 15: ...AN IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the l...

Page 16: ...15 NOTE...