STUDIO DUE 0102 Manual Download Page 13

... 12 ...

DATA LINK (512 DMX) TOUBLESHOOTING
Appendix “C” • Table A2

Ventilation of the head

does not work normally

HEAD FAN connectors

on the PCB MCIP are not

ok

Check tension on the

FAN connector (rif. MCIP

PCB)

The lamp is cutting out

intermittently

The lamp is not working

well.

The values reached by

the internal temperature

are too high

The tension of the

power supply is either

too high or too low.

The fan on the head is

not working regularly

Measure the mains

voltage.

Check and if necessary

replace the fan

One of the function is

not working well(ie.

DIMMER)

Disconnect the power.

Manually test if the

DIMMER moves freely.

The stepper motor is

damaged or the cable

connected to the

controller pcb is broken

(ref. MCIP PCB).

The motor drive (L6219)

is broken.

Problem

Pilot-tests (guide)

Probable cause(s)

Suggested Solutions

None of the

MiniCity250s responds

to controller.

The DMX led is switched

off.

Make sure that all the

units are set in DMX

mode.

After the configuration

reset all the fixtures

The controller is not

connected to the

fixtures.

The cable from the

controller to the first of

the MiniCity250 is

interrupted (or pin 2 and

3 are swapped or the

cables are on short

circuit)

Connect the controller

properly.

Use an already tested

cable and connect the

fixtures one by one.

One or more of the

MiniCity250s do not

respond to the controller

or do it wrongly.

The non-working

fixtures are always the

same.

The fixtures work

accidentally. If one of the

connecting cables is

missing this may cause

a random

malfunctioning in

addition to apparent

normal operation. If the

inverted-data is cut wire

is cut (pin. 2 on the DMX

connector) the line

works intermittently.

Wrong DMX address in

the fixture.

Wrong data cables, or

disconnected or shorted.

One fixture has a broken

DMX board.

DMX link not terminated.

Set the proper address

Check and if necessary

replace the cables.

Use a tested cable and

replace only one at a

time.

Use a tested cable and

exclude only one fixture

at a time.

Insert the terminator on

the last fixture (pag.10)

Summary of Contents for 0102

Page 1: ...ing page 4 Control panel and configuration page 5 Use of the MiniCity250 page 7 DMX signal connection page 8 DMX line and terminator page 9 Automode functioning page 10 Troubleshooting page 11 System...

Page 2: ...ith the following lamp only Philips MSD 250 2 DO NOT USE ANY OTHER TYPE LAMP 2 Maintain minimum distance of 0 3 meter from walls or any other type flammable surfaces 3 Maintain minimum distance to lig...

Page 3: ...mode POWER SUPPLY Rated voltage 230V 50Hz 230V 60Hz on request 117Vac 60Hz 100Vac 50Hz Rated power 350W Rated current 1 7A 230V FUSES Lamp fuse 5 0A 250V delay time Electronic fuse 2 0A 250V delay tim...

Page 4: ...connection cable on the spot when it is warm 1b This unit must be positioned as to allow its ventilation Be careful not to acclude the in out ventilating grilles 1c The unit must be positioned at lea...

Page 5: ...cloth and alcohol 8 Install again the reflector parabole in the original position and screw the two screws A and B again 9 Install again in the correct position the glass cover 10 Check carefully the...

Page 6: ...remotely controlled off lamp switched on DIMMER led flashing the lamp is 33 dimmered off lamp switched on BUTTONS Four buttons are used to programme the spot MENU to select the programming options DOW...

Page 7: ...at the selected option is different from the pre set one The available op tions are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27 for the master functioning with the re specti...

Page 8: ...r CH 6 Beam angle CH 6 Beam angle CH 7 Reset Lamp Off 7 FOCU Focus control To visualise the focus position press ENTER Use Down and Up buttons to change the channel and once the required one has been...

Page 9: ...data transmission sect 2x0 25 gnd If the lines have a total length over 150 200 mts it is suggested to use a signal amplifier art 3004 DMX repeter amplifier The usage of a normal microphonic or audio...

Page 10: ...OGRAMMING SPOTS FUNCTIONS PROGRAMS SPOTS STEPS SELECT PLAY OUT IN DMX repeater amplifier L N L N 9 DMX TERMINAL LINE The wrong connection of the terminal line or its non connection are probably the mo...

Page 11: ...isplay stops flashing it flashes to indicate that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27...

Page 12: ...ted solutions The unit does not turn on the fans do not work The unit is completely dead Measure the mains voltage on the main connector If you have the right value the main fuses are blown No power P...

Page 13: ...the units are set in DMX mode After the configuration reset all the fixtures The controller is not connected to the fixtures The cable from the controller to the first of the MiniCity250 is interrupt...

Page 14: ...EPROTECTION MOT2 DIMMER MOT5 CYAN U12 7805 5V TOHEAD THERMAL SENSOR ANDSWITCH MAINPOWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER U10 MICRO PWM FAN CONTROLLER MOT3 MAGE...

Page 15: ...AN IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the l...

Page 16: ...15 NOTE...

Reviews: