MOTORS BOARD

• POWER 30V Led On
• +5V Led
• +320V Led
•+5V DMX Led
• DMX signal

Led flashing:

the DMX signal is operating on the board

Led off:

check the U1 (6N137) and the DMX connecting cable (from PCB PAN IP)

• STEPPER MOTOR channel not working: (i.e. YELLOW):
1) Switch off the fixture and disconnect the YELLOW and CYAN cables
2) Connect the YELLOW cable on the CYAN connector
3) Switch on the fixture:
3a) If the YELLOW motor works normally it is necessary to replace the U6 (L6219)
3b) If the motor is still not working check with extreme attention the motor and the  interconnecting circuits (cables and

connectors). To check the cables and the motors you can measure the resistance as follows:
between PIN 1 and PIN21 (on IC U6)r=~18ohm; between PIN 2 and PIN5 (on IC U6) r=~18ohm

• If the led +5V OPTODMX is off:
1) Disconnect TO DISPLAY PCB PAN IP connector; if the led is on check PCB PAN IP
2) Check U13 (78M05), L3, D6

• If the led +5V is off:
1) Disconnect TO DISPLAY PCB PAN IP connector; if the led is on check PCB PAN IP
2) Check D4, L2, U12

•If the led +28V is off:
1) Check if the led +320V is on, if it is ok:
1a) Check if U11 is in thermal drift 

(ATTENTION on the heat dissipator there is dangerous tension!!!!)

1b) Check if U5, U6, U7, U8, U9 are in short-circuit.  Switch off  the fixture. Remove all the chips from the socket.

Switch on the fixture: if the led is on, insert the chips one by one in the sockets to find out which is in short-circuit.

1c) Check D3
1d)

If all the operations described above have not given any positive result, change U11

2) If the led +28V is off together with the led +320V
2a) Check the MAIN POWER INPUT where you can measure the working voltage
2b) Check the main fuse, if it is blown check VR1 (normally it has a resistance = 

). If it is in short circuit you must change it.

2c) Check D1 (Bridge Rectifier), if it is ok check C65.
2d)

If the fuse is still blown, change U11

Summary of Contents for 0102

Page 1: ...ing page 4 Control panel and configuration page 5 Use of the MiniCity250 page 7 DMX signal connection page 8 DMX line and terminator page 9 Automode functioning page 10 Troubleshooting page 11 System...

Page 2: ...ith the following lamp only Philips MSD 250 2 DO NOT USE ANY OTHER TYPE LAMP 2 Maintain minimum distance of 0 3 meter from walls or any other type flammable surfaces 3 Maintain minimum distance to lig...

Page 3: ...mode POWER SUPPLY Rated voltage 230V 50Hz 230V 60Hz on request 117Vac 60Hz 100Vac 50Hz Rated power 350W Rated current 1 7A 230V FUSES Lamp fuse 5 0A 250V delay time Electronic fuse 2 0A 250V delay tim...

Page 4: ...connection cable on the spot when it is warm 1b This unit must be positioned as to allow its ventilation Be careful not to acclude the in out ventilating grilles 1c The unit must be positioned at lea...

Page 5: ...cloth and alcohol 8 Install again the reflector parabole in the original position and screw the two screws A and B again 9 Install again in the correct position the glass cover 10 Check carefully the...

Page 6: ...remotely controlled off lamp switched on DIMMER led flashing the lamp is 33 dimmered off lamp switched on BUTTONS Four buttons are used to programme the spot MENU to select the programming options DOW...

Page 7: ...at the selected option is different from the pre set one The available op tions are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27 for the master functioning with the re specti...

Page 8: ...r CH 6 Beam angle CH 6 Beam angle CH 7 Reset Lamp Off 7 FOCU Focus control To visualise the focus position press ENTER Use Down and Up buttons to change the channel and once the required one has been...

Page 9: ...data transmission sect 2x0 25 gnd If the lines have a total length over 150 200 mts it is suggested to use a signal amplifier art 3004 DMX repeter amplifier The usage of a normal microphonic or audio...

Page 10: ...OGRAMMING SPOTS FUNCTIONS PROGRAMS SPOTS STEPS SELECT PLAY OUT IN DMX repeater amplifier L N L N 9 DMX TERMINAL LINE The wrong connection of the terminal line or its non connection are probably the mo...

Page 11: ...isplay stops flashing it flashes to indicate that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27...

Page 12: ...ted solutions The unit does not turn on the fans do not work The unit is completely dead Measure the mains voltage on the main connector If you have the right value the main fuses are blown No power P...

Page 13: ...the units are set in DMX mode After the configuration reset all the fixtures The controller is not connected to the fixtures The cable from the controller to the first of the MiniCity250 is interrupt...

Page 14: ...EPROTECTION MOT2 DIMMER MOT5 CYAN U12 7805 5V TOHEAD THERMAL SENSOR ANDSWITCH MAINPOWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER U10 MICRO PWM FAN CONTROLLER MOT3 MAGE...

Page 15: ...AN IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the l...

Page 16: ...15 NOTE...

Reviews: