STUDIO DUE 0102 Manual Download Page 2

... 1 ...

INTRODUCTION

Thank you for using the MiniCity250.
The projects uses the tested CYM colorchanger system, patent pending, developed by our labs and a new optic system with an
opening angle, which can be varied, driven by two stepper motors. Its performances, in terms of luminousity and lighted surfaces, can
reach incredible levels.

The MiniCity250 comes in one version:

• Art. 0102

MINICITY250 for MSD 250W discharge lamp

The MiniCity250 can work in automatic mode or in synchro mode, otherwise may be controlled by 8 bit DMX controllers

The input protocol is the DMX 512. To drive the MiniCity250 we suggest to use either our controllers: Control Show 512, Fancy or Easy
Control.

To make  the most  of its possibilites and for a correct  functioning of this unit in the years to come, we suggest you to read carefully
this manual before connecting or putting the spot into use. By doing so you will gain experience with its commands and connections
and you will be easily able to use it.

WARNING

!

SAFETY INFORMATION

READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT.

INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS

AND UV RADIATION HAZARDS.

• PROTECTION AGAINTS FIRE

1) This equipment is designed for use with the following lamp only: 

Philips MSD 250/2

     

DO NOT USE ANY OTHER TYPE LAMP!

2) Maintain minimum distance of 0.3 meter from walls or any other type flammable surfaces.
3) Maintain minimum distance to lighted objects of 1.0 meter.
4) Replace fuses only with the specified type and rating.
5) Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm.

• PROTECTION AGAINST ELECTRIC SHOCK

1) This equipment must be earthed.
2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord.
3) For connection to the supply mains proceed as pict.2 page 3.
4) Disconnect power before lamp’s replacement or servicing (service personnel).

• PROTECTION AGAINST MECHANICAL HAZARDS

1) Use secondary safety chain when fixing this equipment.
2) Hot lamp explosion hazard. Do not open the equipment for 5 minutes after switching off.
3) Equipment surface may reach temperature up to 100°C. Allow about 5 minutes before handling.
4) Replace the lamp if it is damaged or thermally deformed.

• PROTECTION AGAINST UV RADIATION HAZARDS

1) Do not start on this equipment without lamp enclosure or if the protection screens, or ultraviolets screens are damaged.
2) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness

has been reduced, for example, by cracks or deep scratches.

3) Do not look directly at the lamp while lamp is on.

Summary of Contents for 0102

Page 1: ...ing page 4 Control panel and configuration page 5 Use of the MiniCity250 page 7 DMX signal connection page 8 DMX line and terminator page 9 Automode functioning page 10 Troubleshooting page 11 System...

Page 2: ...ith the following lamp only Philips MSD 250 2 DO NOT USE ANY OTHER TYPE LAMP 2 Maintain minimum distance of 0 3 meter from walls or any other type flammable surfaces 3 Maintain minimum distance to lig...

Page 3: ...mode POWER SUPPLY Rated voltage 230V 50Hz 230V 60Hz on request 117Vac 60Hz 100Vac 50Hz Rated power 350W Rated current 1 7A 230V FUSES Lamp fuse 5 0A 250V delay time Electronic fuse 2 0A 250V delay tim...

Page 4: ...connection cable on the spot when it is warm 1b This unit must be positioned as to allow its ventilation Be careful not to acclude the in out ventilating grilles 1c The unit must be positioned at lea...

Page 5: ...cloth and alcohol 8 Install again the reflector parabole in the original position and screw the two screws A and B again 9 Install again in the correct position the glass cover 10 Check carefully the...

Page 6: ...remotely controlled off lamp switched on DIMMER led flashing the lamp is 33 dimmered off lamp switched on BUTTONS Four buttons are used to programme the spot MENU to select the programming options DOW...

Page 7: ...at the selected option is different from the pre set one The available op tions are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27 for the master functioning with the re specti...

Page 8: ...r CH 6 Beam angle CH 6 Beam angle CH 7 Reset Lamp Off 7 FOCU Focus control To visualise the focus position press ENTER Use Down and Up buttons to change the channel and once the required one has been...

Page 9: ...data transmission sect 2x0 25 gnd If the lines have a total length over 150 200 mts it is suggested to use a signal amplifier art 3004 DMX repeter amplifier The usage of a normal microphonic or audio...

Page 10: ...OGRAMMING SPOTS FUNCTIONS PROGRAMS SPOTS STEPS SELECT PLAY OUT IN DMX repeater amplifier L N L N 9 DMX TERMINAL LINE The wrong connection of the terminal line or its non connection are probably the mo...

Page 11: ...isplay stops flashing it flashes to indicate that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27...

Page 12: ...ted solutions The unit does not turn on the fans do not work The unit is completely dead Measure the mains voltage on the main connector If you have the right value the main fuses are blown No power P...

Page 13: ...the units are set in DMX mode After the configuration reset all the fixtures The controller is not connected to the fixtures The cable from the controller to the first of the MiniCity250 is interrupt...

Page 14: ...EPROTECTION MOT2 DIMMER MOT5 CYAN U12 7805 5V TOHEAD THERMAL SENSOR ANDSWITCH MAINPOWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER U10 MICRO PWM FAN CONTROLLER MOT3 MAGE...

Page 15: ...AN IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the l...

Page 16: ...15 NOTE...