12
www.stryker.com
EN
0702-002-700 Rev-S
Features
Control Panel (Figure 7)
E
F
G
H
D
C
B
A
O
N
M
L
I
K
J
Figure 7 Control Panel
A
Evacuate Smoke Button
–
Push the button to start or stop
smoke evacuation. See the
Smoke Evacuator Modes of
Operation
table for options.
B
Evacuate Smoke Indicator
–
Illuminates when smoke
evacuator is activated.
C
4L (4-liter) Suction Limit Setting Dial
–
Turn the dial to
adjust the suction limit of the 4-liter canister. The suction
value will be indicated on the control panel display as a
limit SETTING value or an ACTUAL value. See the
Features
,
Control Panel Display Screens
section and the
Definitions
,
Suction Limit Setting Dial Colors
table.
D
Suction Limit Setting Ranges
–
See the
Definitions, Suction
Limit Setting Dial Colors
table section for codes and suction
limit range information before adjusting the SUCTION LIMIT
SETTING dials.
E
Control Panel Display Push Buttons (four)
–
Push the
appropriate button to interact with the display.
F
Control Panel Display
–
Provides suction values for each
canister, system status and error code messages; also
displays wash cycle options during the docking procedure.
Display brightness and contrast may also be adjusted. See the
To Adjust the Rover Settings
section.
G
HIGH VACUUM / HIGH FLOW Continuous Surgical Suction
Range: 50 to 480 mm-Hg –
See the
Specifications
section.
H
System Setup Button
–
Push and hold the button until the
SYSTEM SETUP screen appears with options.
I
IV Pole Buttons
–
Push and hold the UP or DOWN arrow
button to raise or lower the height of the IV pole, respectively.
J
System Setup Symbol
–
Push and hold the push button next
to this symbol to access the SYSTEM SETUP screen and
change rover settings. See the
To Adjust the Rover Settings
section.
K
20L (20-liter) Suction Limit Setting Dial
–
Turn the dial to
adjust the suction limit of the 20-liter canister. The suction
value will be indicated on the control panel display as a
limit SETTING value or an ACTUAL value. See the
Features
,
Control Panel Display Screens
section and the
Definitions
,
Suction Limit Setting Dial Color
section.
L
Empty 4L Canister Button
–
Push the button to transfer
the contents of the 4-liter canister into the 20-liter canister.
Transfer requires confirmation.
M
Suction ON/OFF Button –
Push the button to start or stop
fluid suction.
N
Suction ON/OFF Indicator –
Illuminates when fluid suction is
activated.
O
Reset Volume Button
–
Push the button to reset the fluid
display level of both canisters to zero values. Reset requires
confirmation.
0000016914, Rev. S Effective Date: Mar 11, 2016 9:46:10 AM
Printed Date: Feb 24, 2020 18:26:59 GMT