![Strobel VEB100-7 Mechanic'S Instructions Download Page 30](http://html1.mh-extra.com/html/strobel/veb100-7/veb100-7_mechanics-instructions_1384797030.webp)
26
MA_VEB100-7_A4_181015_en
The flat belt can be exchanged (Fig. 19 (1)) by pressing the base of the press
together.
The base of the press can be re-installed in reverse order.
The running (centrally/straight) of the flat belt can be set at the screw (Fig. 19
(2)). This only works in installed condition though.
Fig. 19
4.5
When mounting the heating cartridges use sliding means 194.0084 to prevent
the cartridges from jamming in the borings which have very little tolerances
because of a good heat transmission.
Using sliding means
4.6
The thermostat sensors are coated with heat conduction paste 290.0139 before
assembly to ensure a good heat transfer. The boreholes are a little larger here,
because the diameter of the copper sensor is not even.
Using heat conducting paste
4.7
The steamed belt loop is dried by means of compressed air in the rear part of
the pressing unit. This air should be free of oil. Therefore connect the air first,
and then the compressed air conditioner
.
Cooling air