![Strobel VEB 200-2 Mechanic'S Instructions Download Page 37](http://html1.mh-extra.com/html/strobel/veb-200-2/veb-200-2_mechanics-instructions_1384791037.webp)
33
MA_VEB200-2_A3_210511_en.doc
At least one cycle needs to be sewn so that the setting is saved before the machine is
switched off.
For class VEB200-1, -1F, -2, -2F:
Position 1
Position 2
P1E
280
P2E
150
P1A
305
P2A
175
For class VEB200-1RF, -2RF:
Position 1
Position 2
P1E
275
P2E
150
P1A
300
P2A
175
Depending on the looper and needle setting, the values could variate slightly.
3.13
Display of the needle positions
Function
Parameter
Display of the Positions 1 and 2 (down / up)
F-172
The setting of the positions can be easily checked using this function.
After entering the code number “1907” and button “E” for the technician level:
-
Select parameter F-172.
Display shows:
.1.7.2.
-
Press “E” button.
Sr 3
-
Turn handwheel according to the motor's direction of rotation.
Display on the control:
Segment 5 is switched on
Position 1E
Segment 5 is switched off
Position 1A
Segment 6 is switched on
Position 2E
Segment 6 is switched off
Position 2A
-
Press “P” button.
.1.7.2.
-
Press “P” button.
Summary of Contents for VEB 200-2
Page 4: ......
Page 19: ...15 MA_VEB200 2_A3_210511_en doc Fig 7...
Page 22: ...18 MA_VEB200 2_A3_210511_en doc Fig 8 Fig 9...
Page 29: ...25 MA_VEB200 2_A3_210511_en doc Fig 15...
Page 43: ...39 MA_VEB200 2_A3_210511_en doc 4 3 Pneumatic circuit diagram with pneum Lifting Efka DC1210...
Page 45: ...41 MA_VEB200 2_A3_210511_en doc 4 5 Pneumatic circuit diagram with seam lock Efka DC1210...
Page 47: ...43 MA_VEB200 2_A3_210511_en doc 4 7 Electric connection diagram Thread trimmer...