FP12 Mundo - Installation and Operation Manual
37
6.3
Fireplace Installation
BEFORE INSTALLING YOUR FIREPLACE, YOU MUST INSTALL THE TWO SPACERS AND THE HEAT SHIELD ON
TOP AND THE TWO SPACERS ON THE BACK OF THE FIREPLACE.
The spacers and the heat shield are in the firebox of the fireplace and the screws are with the manual kit.
Using the screws provided, install the two spacers (A) and the heat shield (B) on top of the fireplace and the
two spacers (C) on the back of it.
6.3.1
Locating the FP12 MUNDO
A.
The best location to install your fireplace is determined by considering the location of windows, doors,
and the traffic flow in the room. Figure some space in front of the unit for the heart extension and the
mantel and taking into consideration the location of the heat distribution systems, the fresh air intake
kit and the chimney. If possible, you should choose a location where the chimney will pass through the
house without cutting floor or roof rafters.
B.
Usually, no additional floor support is needed for the fireplace. The adequacy of the floor can be
checked by first estimating the weight of the fireplace system. Weight is given in
Section 2.1:
FP12
Mundo Specifications
. Next, measure the area occupied by the fireplace, note the floor construction
and consult your local building code to determine if additional support is needed.