MR0012J
9710 System Assurance Guide
4-11
SCSI Cabling
■
SCSI Cabling
The following pages contain SCSI cable and adapter information.
Cable Restriction
Maximum allowed cable lengths (including the lengths already inside the 9710)
are:
•
Single-ended: up to 6 m (20 ft) for up to 5 mega transfers per second
•
Single-ended: up to 3 m (9.5 ft) above 5 mega transfers per second
•
Differential: up to 25 m (82 ft)
Note:
The LSM supports
only
the SCSI Type 3 connector at the LSM I/O panel
(tailgate). Customers using SCSI Type 1 or 2 cable connectors must order
a SCSI-1- or 2-to-SCSI 3 adapter for the LSM-end of their cables to
correctly mate with the LSM.
lists additional restrictions for SCSI connections.
Table 4-3. SCSI Cable Restriction
Application
Length Restriction
Single-Ended
Stub length: 0.1 m (4 in.)
5–10 MHz data transfer rate: 3 m (10 ft)
1–5 MHz data transfer rate: 6 m (20 ft)
Differential
Stub length: 0.2 m (10 in.)
1–10 MHz data transfer rate: 25 m (82 ft)
Summary of Contents for 9710
Page 1: ...9710 Library Storage Module System Assurance Guide Document MR0012 ...
Page 2: ......
Page 3: ...9710 Library Storage Module System Assurance Guide ...
Page 12: ...Tables x 9710 System Assurance Guide MR0012J This page intentionally left blank ...
Page 18: ...Preface xvi 9710 System Assurance Guide MR0012J This page intentionally left blank ...
Page 35: ...MR0012J 9710 System Assurance Guide 3 7 Host Interfaces Figure 3 5 Host Indirect Connection ...
Page 52: ...SCSI Cabling 4 12 9710 System Assurance Guide MR0012J Figure 4 6 SCSI Connector Types ...
Page 80: ...A 6 9710 System Assurance Guide MR0012J This page intentionally left blank ...
Page 85: ......