background image

Hardware Support Services

5-4

9710 System Assurance Guide

MR0012J

 

This page intentionally left blank.

Summary of Contents for 9710

Page 1: ...9710 Library Storage Module System Assurance Guide Document MR0012 ...

Page 2: ......

Page 3: ...9710 Library Storage Module System Assurance Guide ...

Page 4: ...he event of changes the publication will be revised Comments concerning its contents should be directed to Nearline Information Development Storage Technology Corporation One StorageTek Drive Louisville CO 80028 2201 USA 1995 through 1999 Storage Technology Corporation Louisville CO USA All rights reserved ...

Page 5: ...e J Date December 1999 Total number of pages in this document is 86 consisting of the following Pages Disposition Cover Replace entire manual Blank page Title page Copyright page ii iii through xiv 1 1 through 1 6 2 1 through 2 4 3 1 through 3 12 4 1 through 4 30 5 1 through 5 4 A 1 through A 6 Index 1 through Index 2 Reader s Comment Form Business Reply Mailer Blank Page Back Cover ...

Page 6: ...ives Chapter 3 Removed note about AS 400 not supporting 9840 or DLT drives Added host interface graphics Figure 3 2 through 3 6 Added illustration of I O panel that shows Fibre Channel plate in lower left corner Chapter 4 Expanded power cable table with new power cable part numbers Corrected drawing of Centronics 50 pin connector Added new in country media services telephone numbers Added note cla...

Page 7: ...r xiii Documents on CD xiv Electronic Document Center xiv KnowledgeMap xiv Partners Page xiv StorageTek Storefront xiv Comments and Suggestions xv Education xv 1 The System Assurance Process 1 1 System Assurance Team Responsibilities 1 2 The System Assurance Flowchart 1 4 Proposal Acceptance 1 5 System Assurance Planning Meetings 1 5 Order Placement 1 5 Sales Entry Form or Order Worksheet Check 1 ...

Page 8: ...eTek Hardware and Software Support 2 3 Client Processor s Teams 2 3 Hardware Contacts 2 3 Software Contacts 2 3 Channel Partner Team 2 4 Marketing Representative 2 4 Solutions Delivery Systems Specialist 2 4 Solutions Delivery Engineer 2 4 Solutions Delivery Installation Consultant 2 4 3 Product Overview 3 1 Drive Configurations 3 2 Power Distribution Unit PDU 3 2 Host Interfaces 3 3 Data Interfac...

Page 9: ...9 Sun Sparc Workstation 4 20 RS 6000 Bull DPX 20 4 21 SCSI Adapters 4 22 Single Ended Narrow or Fast Narrow to Wide 4 22 High Density 68 68 Pin Standard Jackscrew 4 22 AS 400 Serial Cables 4 23 Sequent Cables 4 23 FIPS Cabling 4 24 FIPS Cables 4 24 FIPS Terminators 4 26 FIPS Drive to I O 4 26 Modem Cables 4 27 Cartridge Tapes and Labels 4 28 5 Pre installation Checklist 5 1 Fire Suppression System...

Page 10: ...on Bus 3 6 Figure 3 5 Host Indirect Connection 3 7 Figure 3 6 Subsystem Generic Software Types 3 8 Figure 3 7 9710 I O Panel Showing FIPS 3 11 Figure 3 8 9710 I O Panel Showing Fibre Channel 3 12 Figure 4 1 9710 Model Feature Selections 4 3 Figure 4 2 DLT8000 Model and Feature Selections 4 5 Figure 4 3 DLT7000 Feature Selections 4 6 Figure 4 4 DLT4000 Feature Selections 4 7 Figure 4 5 4890 Drive F...

Page 11: ...dapters for RS 6000 and Bull DPX 20 4 21 Table 4 13 Adapters SCSI 4 22 Table 4 14 Single Ended Narrow or Fast Narrow to Wide SCSI 4 22 Table 4 15 High Density 68 68 Pin Jackscrew SCSI 4 22 Table 4 16 AS 400 Serial Cables 4 23 Table 4 17 Sequent Cables 4 23 Table 4 18 FIPS Cables 4 25 Table 4 19 FIPS Terminators 4 26 Table 4 20 FIPS Cables 4 26 Table 4 21 Modem Cables 4 27 Table 4 22 Remote Diagnos...

Page 12: ...Tables x 9710 System Assurance Guide MR0012J This page intentionally left blank ...

Page 13: ...ror free installation and customer satisfaction Use only those checklists that are applicable to your system However certain worksheets noted below must be completed for the product to be shipped Refer to Chapter 4 for more information Note If the following worksheets are not completed and sent to Orders Administration the product will not be shipped Library Configuration Worksheet Site Survey Pro...

Page 14: ...or switches onscreen buttons and softkeys appear in Helvetica font and in all capital letters Emphasized text not or must Important or emphasized words and phrases appear in italics Filenames dictionary txt Filenames appear in Courier font Indicators LEDs Open Indicators and LEDs appear with initial capital letters and in italics Keyboard keys Y Enter or Ctrl Alt Delete Keyboard keys appear within...

Page 15: ...ypertext links www stortek com techpubs Universal Resource Locator URL and hypertext links appear in blue text and underlined 9710 Publication Part Number 9710 Library Storage Module Installation Manual 9640 Quantum DLT Publications Part Number DLT4000 Cartridge Subsystem Product Manual 313127601 StorageTek 81 60043 0x Quantum DLT7000 Tape Drive Product Manual 313134501 StorageTek 81 60000 0x DLT8...

Page 16: ...wledgeMap StorageTek s KnowledgeMap is an online service that provides product information general resources white papers and answers to frequently asked questions It also contains information about networks platforms and sales support The KnowledgeMap is for StorageTek employees and distributors The location of the KnowledgeMap is http wwfokm stortek com Partners Page StorageTek s Partners Page i...

Page 17: ...ng tuition and schedules call the registrar at 303 673 6262 Consult the current Corporate Education Course Catalog or view EDUCATION announcements on the intranet using Netscape for the latest offerings and schedules StorageTek employees should follow these steps to register 1 Start Netscape 2 Type the following URL http intwww stortek com 3 At the right side of the screen click on alphabetical 4 ...

Page 18: ...Preface xvi 9710 System Assurance Guide MR0012J This page intentionally left blank ...

Page 19: ...m assurance team members appear across the top of the figure The process is the exchange of information among the team members to ensure that no aspects of the sale ordering and installation are overlooked This promotes an error free installation and contributes to customer satisfaction Figure 1 1 The System Assurance Overview ...

Page 20: ...ings between team members Supplies or obtains all necessary support documentation Works with the customer to complete the following worksheets Key personnel Chapter 2 Hardware configuration Chapter 4 Site survey Chapter 4 Receiving dock information Chapter 5 Inside delivery information Chapter 5 Access and administrative issues Chapter 5 Faxes all of the required and completed work sheets except t...

Page 21: ... listed for the SDIC Works with the solutions delivery systems specialist SDSS at the system assurance planning meetings to provide the data for the worksheet listed for the SE Names a contact person for any unresolved issues in the above worksheets Discusses the schedule and names a contact per son for all scheduling matters Solutions Delivery Systems Specialist SDSS Explains available levels of ...

Page 22: ...wchart Figure 1 2 shows the system assurance process flow The following pages describe the steps in more detail No two installations are the same however following this flowchart promotes a smooth system assurance process and an error free installation Figure 1 2 The System Assurance Process Flow ...

Page 23: ...on worksheets order worksheets and other required worksheets Chapter 4 Set the dates and times for one or more system assurance review meetings Order Placement Depending on the customer the appointed team member must now either Fax the completed worksheets to Orders Management OM or Transfer information from the completed worksheets to the sales entry form and fax the sales entry form to the Share...

Page 24: ...exceptions to the original shipment The system assurance team leader completes the reader s comment form at the back of this guide or online to submit any comments on this guide Refer to the end of the How This Guide is Organized on page xi for the fax number address and URL The SDE logs installation data into the Customer Services Data Collection CSDC system The SDE attends a follow up meeting wi...

Page 25: ...home ________________ Operating Systems Software Contact ___________________________________________________________ Phone office ________________ home ________________ Communication Hardware Contact ___________________________________________________________ Phone office ________________ home ________________ Operations Contact ___________________________________________________________ Phone off...

Page 26: ...__ Solutions Delivery Systems Specialist ___________________________________________________________ Phone office ________________ home ________________ Solutions Delivery Engineer ___________________________________________________________ Phone office ________________ home ________________ SDE room on site Solutions Delivery Installation Consultant _______________________________________________...

Page 27: ... home ________________ _____________________________________________________________ Phone office ________________ home ________________ Software Contacts _____________________________________________________________ Phone office ________________ home ________________ _____________________________________________________________ Phone office ________________ home ________________ _________________...

Page 28: ..._______ Solutions Delivery Systems Specialist ___________________________________________________________ Phone office ________________ home ________________ Solutions Delivery Engineer ___________________________________________________________ Phone office ________________ home ________________ SDE room on site Solutions Delivery Installation Consultant __________________________________________...

Page 29: ... drive configurations and interfaces The 9710 library consists of An LSM that stores 224 to 588 tape cartridges A cartridge access port CAP that stores up to 14 cartridges 9840 Digital Linear Tape DLT or 4890 drives installed behind the LSM right front door Figure 3 1 9710 LSM with Expansion Door C60485 ...

Page 30: ...90 and DLT drives within the same LSM No more than six 4890 drives may be installed The DLT drives must be installed above the 4890 drives When installing only DLT drives A maximum of 10 drives may be installed per LSM When mixing 9840 and DLT drives within the same LSM No more than six DLT drives may be installed The DLT drives must be installed above the 9840 drives You may mix SCSI and Fibre Ch...

Page 31: ...connections to the LSM a server Unix based using Automated Cartridge Server Library ACSLS software or a RISC System 6000 using the Advanced Interactive Executive AIX operating system is connected between the host and the LSM An example of an indirect connection is an LSM hooked to a Unix server with the server connected to an Ethernet LAN network A cable is run from the Ethernet LAN to the host se...

Page 32: ...Host Interfaces 3 4 9710 System Assurance Guide MR0012J Figure 3 2 Direct Connection for AS 400 Control ...

Page 33: ...MR0012J 9710 System Assurance Guide 3 5 Host Interfaces Figure 3 3 Client Configuration Indirect Connection with AS 400 ...

Page 34: ...Host Interfaces 3 6 9710 System Assurance Guide MR0012J Figure 3 4 SCSI Direct Connection Open Systems with Common Bus ...

Page 35: ...MR0012J 9710 System Assurance Guide 3 7 Host Interfaces Figure 3 5 Host Indirect Connection ...

Page 36: ...Host Interfaces 3 8 9710 System Assurance Guide MR0012J Figure 3 6 Subsystem Generic Software Types ...

Page 37: ...s connectors You may use only one SCSI data bus input per drive The other connector must be terminated or it can be used for daisy chaining in a non AS 400 environment but it cannot be used for a second data bus DLT Data Buses Each DLT has two SCSI data bus connectors You can use only one SCSI data bus input per drive The other connector must be terminated or it can be used for daisy chaining but ...

Page 38: ...currently are not used RS423 The 9710 uses RS423 electronics in its control interface rather than RS232 The RS423 and RS232 protocols are the same but the RS423 electronics can drive a signal to greater distances The maximum RS423 cable length is 60 m 200 ft SCSI Library Robotic Interface The fast narrow interface is single ended or differential and supports up to eight devices including the host ...

Page 39: ...tic Interface Note The 3270 control interface ports shown in Figure 3 7 on page 3 11 are not presently used One of the two SCSI control interface ports is used for the control line the other is reserved for daisy chaining Figure 3 7 9710 I O Panel Showing FIPS ...

Page 40: ... MR0012J Note The 3270 control interface ports shown in Figure 3 8 on page 3 12 are not presently used One of the two SCSI control interface ports is used for the control line the other is reserved for daisy chaining Figure 3 8 9710 I O Panel Showing Fibre Channel ...

Page 41: ...ormation from the order worksheets to a sales entry form 8 Fax the order worksheets or sales entry form to the appropriate orders department Fax Numbers and Addresses The orders department the fax number and the documents to fax depend on the customer The department addresses and voice phone numbers are for your information Domestic customers value added distributors VADs and value added resellers...

Page 42: ...es in Canada Japan Australia South Asia and Mexico must fax the following forms to Orders Management Hardware order worksheet Cables order worksheet Site survey Orders Management Fax 1 303 673 2640 for distributors or subsidiaries Fax 1 303 673 7654 for OEM One StorageTek Drive Louisville CO 80028 4350 Voice 1 303 673 5513 Hardware Order Worksheets Use the following paragraphs and worksheets to pl...

Page 43: ...MR0012J 9710 System Assurance Guide 4 3 Hardware Order Worksheets Note Both feature codes 1603 and 2016 include two serial ports and do not include a SCSI card Figure 4 1 9710 Model Feature Selections ...

Page 44: ...You will need SCSI Fast Wide 68 pin connectors to connect to the differential drives Note The DLT8000 is only available with a differential interface Each kit contains one DLT drive differential terminator slides drive mounting tray drive actuator mechanism drive chassis DLT power supply cooling hardware to mount the drive to the tray and the drive power cord Note If more than six drives are order...

Page 45: ...MR0012J 9710 System Assurance Guide 4 5 Hardware Order Worksheets Figure 4 2 DLT8000 Model and Feature Selections ...

Page 46: ...Hardware Order Worksheets 4 6 9710 System Assurance Guide MR0012J Figure 4 3 DLT7000 Feature Selections ...

Page 47: ...MR0012J 9710 System Assurance Guide 4 7 Hardware Order Worksheets Figure 4 4 DLT4000 Feature Selections ...

Page 48: ...heets 4 8 9710 System Assurance Guide MR0012J 4890 Drives Figure 4 5 lists the 4890 drive feature numbers CAUTION You may not install 9840 drives and 4890 drives within the same LSM Figure 4 5 4890 Drive Feature Selections ...

Page 49: ...83241 ________ Cable assembly South Korea 100 127 V VCTF cord 3 x 1 25 mm2 KSC 8305 plug For optional PDU 10083657 ________ Cable assembly domestic twisted lock 200 240 V 20 A 2 5 m 8 2 ft 14 AWG SJT cord For main PDU 10083638 ________ Cable assembly domestic twisted lock 200 240 V 15 A 2 5 m 8 2 ft 16 AWG SJT cord For optional PDU 10083639 ________ Cable assembly domestic 100 127 V 20 A 3 m 10 ft...

Page 50: ... Cables 9710 to Host Description Part Number Quantity Cable assembly DB9 F DB24 F 4 m 13 ft 310227101 ________ Cable assembly DB9 F DB24 F 6 m 20 ft 310227201 ________ Cable assembly DB9 F DB24 F 12 m 39 4 ft 310227301 ________ Cable assembly DB9 F DB24 F 24 m 79 ft 310227401 ________ ...

Page 51: ...al up to 25 m 82 ft Note The LSM supports only the SCSI Type 3 connector at the LSM I O panel tailgate Customers using SCSI Type 1 or 2 cable connectors must order a SCSI 1 or 2 to SCSI 3 adapter for the LSM end of their cables to correctly mate with the LSM Table 4 3 lists additional restrictions for SCSI connections Table 4 3 SCSI Cable Restriction Application Length Restriction Single Ended Stu...

Page 52: ...SCSI Cabling 4 12 9710 System Assurance Guide MR0012J Figure 4 6 SCSI Connector Types ...

Page 53: ...subtract 1 2 m 4 ft from the control or data bus The AS 400 does not allow daisy chains Table 4 4 SCSI Cable Length Subtraction Number of drives on the same data bus Are data and control on the same bus Yes No Subtract this value from maximum allowed cable length 1 always 1 for AS 400 no always no for AS 400 1 2 m 4 0 ft from drive bus 2 4 m 8 0 ft from control bus 2 no 1 7 m 5 5 ft from drive bus...

Page 54: ... 15 5 ft from bus 1 7 yes 5 2 m 17 0 ft from bus 1 8 yes 5 6 m 18 5 ft from bus 1 9 yes 6 m 20 0 ft from bus 1 10 yes 6 6 m 21 5 ft from bus 1 Note 1 Calculated for a control interface daisy chain cable of 0 5 m 18 in Add 0 8 m 2 5 ft for a 1 2 m 4 ft cable and 1 1 m 4 5 ft for a 1 8 m 6 ft cable Table 4 4 SCSI Cable Length Subtraction Continued Number of drives on the same data bus Are data and c...

Page 55: ...External Interface Cable 3 m 10 ft 10083313 _____ Type CL2 SCSI External Interface Cable 6 m 20 ft 10083310 _____ Type CL2P SCSI External Interface Cable 6 m 20 ft 10083314 _____ Type CL2 SCSI External Interface Cable 15 m 49 ft 10083311 _____ Type CL2P SCSI External Interface Cable 15 m 49 ft 10083315 _____ Type CL2 SCSI External Interface Cable 20 m 65 ft 10083312 _____ Type CL2P SCSI External I...

Page 56: ...54001 ________ SCSI cable assembly 2 130 mm 84 in 1 6 control 313115701 ________ SCSI cable assembly 460 mm 18 in 310292001 ________ SCSI cable assembly 1 220 mm 48 in 7 10 control 310292101 ________ SCSI cable assembly 250 mm 10 in 9840 313109302 ________ SCSI cable assembly 460 mm 18 in 9840 310292001 ________ Table 4 7 Daisy Chain Terminators x Description Part Number Quantity Terminator fast w...

Page 57: ... Location Cable Length Part Number Quantity 9 1220 mm 48 in 310292101 ________ 8 1220 mm 48 in 310292101 ________ 7 1220 mm 48 in 310292101 ________ 6 1830 mm 72 in 310254001 ________ 5 1830 mm 72 in 310254001 ________ 4 1830 mm 72 in 310254001 ________ 3 1830 mm 72 in 310254001 ________ 2 1830 mm 72 in 310254001 ________ 1 2130 mm 84 in 313115701 ________ 0 2130 mm 84 in 313115701 ________ ...

Page 58: ...al x Description Part Number Quantity SCSI cable assembly 68 M pin to 68 pin F 2 440 mm 96 in PRS to I O panel 310294201 ________ SCSI cable assembly 68 M pin to 68 pin M 40 mm 18 in PRS to drive daisy chain 310292001 ________ SCSI cable assembly 68 M pin to 68 pin M 1 220 mm 48 in PRS to drive daisy chain 310292101 ________ SCSI cable assembly 68 M pin to 68 pin M 1 820 mm 72 in PRS to drive dais...

Page 59: ... Quantity IBM 68 68 pin AS 400 interposer connector is an adapter connector to attach standard 68 68 pin SCSI cables to the AS 400 Order this connector if you already have standard SCSI cables on site If you do not order only the cables below 05H3834 order from IBM ________ AS 400 special 68 68 pin SCSI cable 3 m 10 ft goes above floor 100821102 ________ AS 400 special 68 68 pin SCSI cable 3m 10 f...

Page 60: ...uantity StorageTek 3 m 10 ft cable to attach the 9710 directly to the Sun Sparc workstation motherboard or to a station with SBE S fast narrow differential or RSBE S fast narrow single ended 10083522 ________ Standard 68 68 pin SCSI cable With this workstation interface feature standard SCSI cables can be used without adapters DWIS S fast wide differential ________ ...

Page 61: ...M 68 68 pin RISC System 6000 Interposer connector This is an IBM adapter connector to attach standard 68 68 pin SCSI cables to RISC System 6000 with interface feature code 2416 fast wide differential Use with one of the standard 68 68 pin cables 50G0460 order from IBM ________ IBM 68 68 pin RISC System 6000 Interposer connector This is an IBM adapter connector to attach standard 68 68 pin SCSI cab...

Page 62: ...arrow to wide bus 50 to 68 pin 10148010 ________ Table 4 14 Single Ended Narrow or Fast Narrow to Wide SCSI x Description Part Number Quantity Cable assembly 50 M D Squeeze Lock 68 M D Screw Lock 3 m 10083522 ________ Table 4 15 High Density 68 68 Pin Jackscrew SCSI x Cable Length Metric English Above Floor Cable P N Plenum under floor Cable P N Quantity 3 m 10 ft 10083309 10083313 ______ 6 m 20 f...

Page 63: ...e assembly serial AS 400 12 m 39 ft 310227301 ________ Cable assembly serial AS 400 24 m 79 ft 310227401 ________ Table 4 17 Sequent Cables x Description Part Number Quantity SCSI DIFF TM 68 pin 5 m 16 4 ft 308398701 ________ SCSI DIFF TM 68 pin 10 m 33 ft 308398801 ________ SCSI DIFF TM 68 pin 0 3 m 1 ft 308398901 ________ SCSI DIFF TM 68 pin 1 2 m 4 ft 308399001 ________ SCSI DIFF TM 68 pin 7 5 ...

Page 64: ...al Style The Bus and Tag cables come in pairs The Internal Style cable is a single cable with a shorter length limit A Y serpentine adapter cable may have to be used depending on the AS 400 IOP and FIPS cable types Cabling configurations are shown in Figure 4 7 Part numbers are listed below The flagged 4 digit IBM part numbers must be ordered from IBM Figure 4 7 FIPS AS 400 Cabling Configurations ...

Page 65: ...5 6 ft 9928 order from IBM ________ Internal Style cable 6 6 m 22 ft 9929 order from IBM ________ Internal Style cable 24 m 79 ft 9930 order from IBM ________ Bus and tag cable pair 3 m 10 ft 305436010 ________ Bus and tag cable pair 15 24 m 50 ft 305436050 ________ Bus and tag cable pair 23 m 75 ft 305436075 ________ Bus and tag cable pair 31 m 100 ft 305436100 ________ Bus and tag cable pair 61 ...

Page 66: ... requires additional terminators FIPS Drive to I O The FIPS cable is listed below Table 4 19 FIPS Terminators x Description Part Number Quantity Terminator FIPS Bus 10041793 ________ Terminator FIPS Tag 10041794 ________ Table 4 20 FIPS Cables x Description Part Number Quantity FIPS cable assembly from drive to I O panel 310259302 ________ ...

Page 67: ...08289 05 ________ 31 m 100 ft 4108289 10 ________ 46 m 150 ft 4108289 15 ________ 61 m 200 ft 4108289 20 ________ 76 m 250 ft 4108289 25 ________ Table 4 22 Remote Diagnostic Support for PC Use x Description Part Number Quantity Cable assembly RJ45 8 pin M RJ45 8 pin M 6 m 20 ft 410828902 ________ Cable assembly RJ45 8 pin M RJ45 8 pin M 15 m 50 ft 410828905 ________ Cable assembly RJ45 8 pin M RJ...

Page 68: ... cartridges Order cartridge tapes and labels by including the order on the sales entry form if used the media portion of the order will be routed to the appropriate department Orders for domestic customers valued added distributors VADs and value added resellers VARs 5390 Triangle Parkway Suite 300 Norcross GA 30092 Voice 1 800 905 8502 Media Service Center Fax 1 877 888 0609 Orders from distribut...

Page 69: ...and 1800 55 33 54 Italy 167 790 852 Norway 800 11 220 South Africa 0800 99 5820 Spain 900 99 33 66 Sweden 020 798711 Switzerland 0800 83 87 65 United Kingdom 0800 731 8852 World Brazil 55 11 5185 2850 Japan 3 3746 9824 Singapore 65 774 9248 Kuala Lumpur 60 3 233 6102 China 86 10 6841 2211 Thailand 662 656 8873 Hong Kong 852 8200 0791 Table 4 23 In Country Media Supply Services Sheet 2 of 2 Region ...

Page 70: ...Cartridge Tapes and Labels 4 30 9710 System Assurance Guide MR0012J This page intentionally left blank ...

Page 71: ...d Due Date Person Responsible Site Preparation Floor plans completed Clearance adequate Cooling adequate Power requirements met Cable lengths determined Cable routing established Future expansion considered Dock facilities scheduled Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Hardware Procurement Subsystems ordered Power cables ordered Options or features ordered Interface cables order...

Page 72: ...2 lists the remote support hardware and cables to provide remote support for the customer Software Installation Scheduled Completed Yes No Yes No Hardware Installation Delivery schedule completed Dock hours scheduled Pre staging area set Installation team identified Site access arranged Installation hours defined Yes No Yes No Yes No Yes No Yes No Yes No Table 5 2 Remote Support Hardware and Cable...

Page 73: ...UT interconnect 150 ft MARS UUT interconnect 200 ft MARS UUT interconnect 250 ft MARS UUT interconnect 410828902 410828905 410828910 410828915 410828920 410828925 7 7 7 7 7 7 Modem MARS Interconnect Cable 4 ft modem to MARS interconnect DB 25 to DB 9 4895 9 Table 5 2 Remote Support Hardware and Cables Continued Equipment Description Part Number Ref Number ...

Page 74: ...Hardware Support Services 5 4 9710 System Assurance Guide MR0012J This page intentionally left blank ...

Page 75: ...ith covers 1490 mm 59 in Depth 790 mm 32 in Depth with expansion door 1020 mm 40 in Weight of base unit with arrays 339 kg 747 lbs Weight of base unit with expansion door and arrays 375 kg 826 lbs Table A 2 LSM Power Specifications Power cable U S Canada 100 VAC UL CSA power cable International 200 240 VAC HAR power cable Input voltage range Nominal voltage 100 254 VAC 120 or 240 VAC Power configu...

Page 76: ...hase 200 240 VAC 47 63 Hz 3 A Service 3 wire Power consumption 38 W Maximum heat output 128 Btu hr Table A 4 LSM Environmental Specifications Temperature Operating Storage Shipping 15 to 32 C 59 to 90 F 10 to 40 C 50 to 104 F 10 to 40 C 50 to 104 F Relative Humidity Operating Storage Shipping 20 to 80 noncondensing 10 to 95 noncondensing 10 to 95 noncondensing Wet Bulb Maximum Operating Storage Sh...

Page 77: ...OUT SEE NOTE 1 148 82 58 59 153 26 60 34 149 12 58 71 153 57 60 46 NOTES 1 2 3 91 44 cm 3 0 ft access required during installation Library may then be pushed back against a wall and stablilized Cable cutout is optional as cables may be routed above the floor For raised floor installation a 15 24 x 61cm 6 X 24 in cutout is recommended if FIPS cables are used The dimensions in parentheses are in inc...

Page 78: ...P supplied by client 9710 120 VAC domestic wall receptacle NEMA 5 20R supplied by client PDU 120 VAC domestic wall receptacle NEMA 5 15R supplied by client International plugs and receptacles for 9710 and if applicable for PDU May be supplied by client according to local electrical codes See power specifications below See Table 4 1 on page 4 9 Current input for library without drives 1 1 250 A at ...

Page 79: ...070 Peak 060 Continuous Heat output for library without drives 680 BTU hr Heat output for each 4890 drive 880 BTU hr Heat output for each DLT drive 257 BTU hr Note 1 Up to six drives take power from the 9710 Four additional drives take power from the PDU box Power ratings for the 9710 and separately for the PDU are figured by also adding the number of drives connected to each The PDU box by itself...

Page 80: ...A 6 9710 System Assurance Guide MR0012J This page intentionally left blank ...

Page 81: ...connections 3 3 conventions in manual xii CPU hardware contact 2 1 CPU vendor 2 3 customer team members 2 1 D delivery contact 2 1 dimensions A 1 drives configurations for 3 2 E Ethernet 3 3 external cables FIPS 4 26 SCSI 4 15 AS 400 data path 4 19 Bull DPX 20 4 21 RS 6000 4 21 Sequent 4 23 Sun Sparc workstation 4 20 F fax number Atlanta Shared Services Center 4 2 cartridge and label orders 4 28 O...

Page 82: ...PARC5 library software 3 3 specifications LSM environmental A 2 PDU A 2 power A 1 power A 4 SCSI cable length 4 11 StorageTek call center 2 3 hardware support 2 3 marketing representative 2 2 2 4 SDE 2 2 software support 2 3 solutions delivery systems specialist 2 2 2 4 team members 2 2 system assurance definition of process 1 1 flowchart 1 4 planning meetings 1 5 postinstallation follow up 1 6 pr...

Page 83: ... reverse side of this form Thank you for your cooperation No postage stamp is required if mailed in the U S A Manual Name ___________________________________________ Manual PN _______________ Field Engineer Manager Programmer Systems Analyst Engineer Mathematician Sales Representative Systems Engineer Instructor Operator Student Trainee Other explain below Introductory text Reference Manual Studen...

Page 84: ... __________________________________________________________ Company Name ______________________________ Department _____________ Street Address _______________________________________________________ City ________________________________________________________________ State _______________________________________ Zip Code _______________ STORAGE TECHNOLOGY CORPORATION ONE STORAGETEK DRIVE Louisvi...

Page 85: ......

Page 86: ...35 Fax 719 536 4053 1999 Storage Technology Corporation Louisville CO All rights reserved Printed in USA StorageTek the signature and Information Made Powerful are trademarks of Storage Technology Corporation Other product names mentioned may be trademarks of Storage Technology Corporation or other vendors manufacturers ...

Reviews: