A-4
9710 System Assurance Guide
MR0012J
Table A-5. Power Characteristics
Description
Value / Part Identification
Picture
Power drops for 9710 and PDU
1
,
each:
(47-63 Hz AC range. 3-wire cables
supplied. International cables are
supplied without cable connectors)
U.S./Canada: 120 VAC, single phase
International: 200-240 VAC, single
phase
9710 120 VAC domestic plug feature
code 70DD
NEMA 5-20P, supplied with 9710
PDU 120 VAC domestic plug
NEMA 5-15P, supplied by client
9710 120 VAC domestic wall
receptacle
NEMA 5-20R, supplied by client
PDU 120 VAC domestic wall
receptacle
NEMA 5-15R, supplied by client
International plugs and receptacles
for 9710 and, if applicable, for PDU
May be supplied by client according to
local electrical codes. See power
specifications below. See
Current input for library without
drives
1
1.250 A at 120 VAC
0.625 A at 240 VAC
2.000 A at 120 VAC
Current input for each 4890 drive
1
1.000 A at 240 VAC
0.60 A at 120 VAC
0.30 A at 240 VAC
Power usage for library without
drives
1
Watts 150 peak / 100 Continuous
KVA 0.15 Peak / 0.10 Continuous
Summary of Contents for 9710
Page 1: ...9710 Library Storage Module System Assurance Guide Document MR0012 ...
Page 2: ......
Page 3: ...9710 Library Storage Module System Assurance Guide ...
Page 12: ...Tables x 9710 System Assurance Guide MR0012J This page intentionally left blank ...
Page 18: ...Preface xvi 9710 System Assurance Guide MR0012J This page intentionally left blank ...
Page 35: ...MR0012J 9710 System Assurance Guide 3 7 Host Interfaces Figure 3 5 Host Indirect Connection ...
Page 52: ...SCSI Cabling 4 12 9710 System Assurance Guide MR0012J Figure 4 6 SCSI Connector Types ...
Page 80: ...A 6 9710 System Assurance Guide MR0012J This page intentionally left blank ...
Page 85: ......