Page 28
Technical Information 40.2010
TI_40_2010_13_01_02.fm
Leads between diagnostic jack and control unit
.
Insert the thick black lead (
5
) between
diagnostic jack (
2
) and switch gear (
3
) in the
guides
.
Insert the thick red lead (
6
) between diagnostic
jack (
2
) and switch gear (
3
) in the guides
Make certain that in area (
A
) the leads (
5
,
6
) are in
two separate guides and in area (
B
) the leads are in
the same guide – black lead (
5
) under the red
lead (
6
).
9.8.2
Cable routing at the switch gear
.
Insert the black lead (
1
) from the plug (
2
) of the
solenoid in the guide
.
Insert the black lead (
3
) from the diagnostic
jack (
4
) in the guide
.
Insert the red lead (
5
) from the diagnostic
jack (
4
) in the guide
.
Insert the red lead (
6
) from the plug (
2
) of the
solenoid in the guide
9.8.3
Cable routing between switch gear and
solenoid
.
Install bushing with switch gear – set choke
lever to position
F
.
Insert plug (
1
) at solenoid as far as it will go
.
Insert black lead (
2
) and red lead (
3
) between
switch gear and solenoid in the guide – black
lead (
2
) under the red lead (
3
)
9.8.4
Cable routing in cable holder
.
Fasten cable holder (
1
) to clutch housing with a
screw (
2
)
.
Insert black lead (
3
) (switch gear) in the guide –
connector tag and terminal socket on the black
lead are welded and cannot be separated
3
B
2