Page 17 of 31
FEED
Touch
to open the feeding overview screen:
•
Silo contents.
•
Current silo state (green = current silo,
blue
= silo blocked,
gray
= silo empty).
•
Calculated number of days that feeding from the silo in question is still possible (this
calculation is based on “yesterday's” amount fed).
•
Silo weigher state
(is displayed only if the feed weigher = PFB-35/70 or PSW-1 is)
.
•
Overview of components
(is displayed only if the feed weigher = PFB-35/70 or PSW-1 is)
.
Note: The “Feed” menu does not appear if the feed weigher is set to PFV-92xx.
FEED WEIGHING
COMPONENT NAMES
•
Set number of components.
•
Change component names.
•
Switch alternative component on/off.
SILO CONTENT / STATE
1 silo
•
Display of component per silo.
•
Display of current silo contents (amount in stock or shortage).
•
Enter the amount filled. After confirming your input, the amount filled is
automatically added to the silo contents and “Filled” is cleared.
Silo state:
The status changes to “empty” if any of these events occur:
•
A manual change of status.
•
No supply of feed from the selected silo.
•
The feed supply speed is too low.
The “empty” status is cancelled as a result of the following:
•
A manual change of status.
•
At “Beginning new day”
•
After restarting the feed weigher (see page 19).
•
By briefly pressing the [ RESET ] key on the PFB feed weigher.
•
Reset alternative components (see page 18).
•
Bulking.
The status changes to “blocked” if any of these events occur:
•
The status is changed to “blocked” by hand. The silo is blocked; feeding
from the silo is no longer possible. If an alternative type of feed has been
set, the alternative feed will be fed.
The “blocked” status is cancelled as a result of the following:
•
A manual change of status to “free” or “empty”.
•
Bulking.
Several
silos
1
9,296
kg
14
days
Component 1