Assembly collectors
Multi-row collector fields with distance metal sheets
It is possible to assemble metal sheets between the collectors to achieve a homogeneous appearance of the
installation. The distance metal sheets are assembled exclusively for optical aspects and do not have any
influence on the installation. Therefore the distance metal sheets can be ordered optionally and are not necessarily
included in delivery.
In multi-row installations the collectors are mounted adjoining. The lip (collector covering) must be cut out in the
appropriate places to install the distance metal sheets easily .
prepared cutting points in all corners of
the underside of the lip (collector covering)
The prepared cutting points of the EPDM-covering of each lower
collector are cut out to assemble the distance metal sheets correctly.
Pay attention that only the horizontal cutting points are cut out.
With a knife cut off carefully the prepared cutting points on the lip
(collector covering).