Assembly plain tile clamps
with lead
Fixation of the lower lath 24x80x600 mm with two screws 4x50 mm.
Assembly of the upper tile clamp support 100x80x25 mm with two
screws 5x60 mm.
When mounting the field in regions with snow load zone III and
higher or with expected increased snow loads, it is necessary to
place the roof hooks in the rafter area.
Assembly of the lower tile clamp supporte 80x50x45 mm with two
screws 5x60 mm.
Timber excess length of 5 mm (timber is higher than tile).
Completely mounted timber supports.
Mount the lower lead sheet while placing the lead laterally under the
tiles.
Pay attention that the corners are bent under the tile on both sides.
1410002 Roof-tile clamp V2 plain tile with lead