27
Assembly collectors
Before mounting the following collectors, the compensator has to be
installed on the flush protruding copper flange.
It is important to ensure that the o-ring seal is used for the
compensator.
1300001 Collector connection set hydraulical
Fixation of the compensator on one side with the clamp.
Before tightening of the screw the clamp must be positioned by a
rotary motion up and down. Tighten the screw on the clamp only
manually. The use of cordless drill or similar may cause damages
on the thread of the clamp. Tighten the clamp until the two lugs
superimpose in the whole length.
1910001 Tool set
Completely installed compensator with O-ring seal.
Fastening plate double slightly fixed.
Prepare assembly of the next collector on the upper and the lower
side of the collector as shown in the picture.
Put the collector on the fastening profile and push it carefully to the
already assembled collector. Pay attention that the compensators
are properly inserted.
Summary of Contents for FKA 240 Series
Page 1: ...1 Assembly Instructions Solar collectors FKA 240 270 Roof mounted installation...
Page 36: ...36 Initial operation 0 1 2 3 4 2 5 3 6 7 8 9 6 1 0 3 1 6 2 3 6 6 5 5...
Page 37: ...37 Initial operation Schematic drawing of the system construction and piping scheme...