English
N.B.
The electrical connection may only be carried out by authorised per-
sonnel. Do not use the device as a mechanical endstop. Any mounting
position is possible. Reconstruction and alterations to the device
are not allowed. The described products were developed in order to
assume safety functions as part of an entire plant or machine. A com-
plete safety system normally covers sensors, monitoring modules,
indicator switches and concepts for safe disconnection. Therefore, a
validation according to EN ISO 13849-2 or EN 62061 is necessary.
Fur-
thermore, the Performance Level according to EN ISO 13849-1 and
SIL CL Level according to EN 62061 can be lower than the single level
because of the combination of several safety components and other
safety-related devices, e.g. by serial connection of sensors.
It is the
responsibility of the manufacturer of a plant or machine to guarantee
the correct general function. Subject to technical modifications.
Service, maintenance, repair
=
DANGER
Live parts.
Electric shock hazard!
Do not repair de-
fective or damaged devices.
Replace them.
Excep-
tion: Use steute’s original spare parts only to repair
the device.
Do not rebuild or modify the device in
any way.
With rough conditions, we recommend routine maintenance as follows:
1. Check actuator for easy operation.
2. Remove all dirt particles.
3. Check sealing of the cable or conduit connections.
Cleaning
=
DANGER
Live parts.
Electric shock hazard!
Observe degree
of protection.
- In case of damp cleaning: use water or mild, non-scratching,
non-chafing cleaners.
- Do not use aggressive cleaners or solvents.
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately.
Installation, mounting, dismantling
=
DANGER
Live parts.
Electric shock hazard!
Connecting and
disconnecting only to be performed by qualified and
authorised personnel. Connecting and disconnect-
ing only in zero potential state.
=
DANGER
Untight if mounted at low temperatures.
Electric
shock hazard!
Mount carefully at low temperatures.
CAUTION
Incorrect installation causes leakage.
Danger of
malfunction.
Only operate with an actuator. Use fit-
ting cable gland only. Observe tightening torque of
cover and actuator.
Mount the device on an even surface. Ensure that the device cannot
be moved from its position. Ensure this in case of failure, too. FFor
protection against unauthorised manipulation, use e.g. one-way safety
screws. These are optionally available.
When mounting the device,
observe the requirements of EN 14119, especially the sections 5.1 to
5.4!
Observe the instructions in the standards EN ISO 12100 and
EN ISO 14120.
Application and operation
=
DANGER
Live parts.
Electric shock hazard!
Protective cover
over contacts must be intact.
=
DANGER
In case of overloaded contacts too high operation
temperatures.
Risk of burns!
For short-circuit
protection use appropriate fuse size (see technical
data).
CAUTION
High temperatures.
Risk of burns!
Observe permit-
ted ambient temperatures.
- Use device only within the permitted electrical load limits (see
technical data).