EMERGENCY RELEASE
In emergency situations it is possible to lower the lifting columns manually.
Manual lowering must only be performed by a qualified engineer.
7.
INSPECTION AND MAINTENANCE
7.1
GENERAL
All maintenance on the lifting equipment must be performed only by trained lift service
personnel.
During inspection and maintenance the columns should be in the lowest position and the main switch should
be turned off. This means that the main switch should be turned to the 0 position and is to be secured with a
padlock.
The current should be turned on again only for the adjustments and checks that require it.
Lubrication chart
The columns must be regularly serviced as listed.
Once a year the lift must be subjected to a highly detailed check and inspection.
You can have the car lift professionally checked by STERTIL mechanics by entering into a maintenance
contract.
Maintenance and inspection
Description
Monthly
yearly
Cylinder
Lubricate dry piston rod (machine oil)
X
Check oil level in reservoir
Top up (with car lift at ground level only)
X
Several pivot points
Grease
X
HYDRAULIC OIL
It is strongly recommended that the hydraulic oil be changed at least every 2 years, irrespective of the
amount of use to which the lift is subjected.
Quantity of oil: 2.6 gallon
OIL CHANGING
1. Lower lift to fullest extent and drain all the oil.
2. Refill with hydraulic oil UNIL HVC S15 (ISO VG 15), filtered at 4 micron max.
7.2
DAILY (BY OPERATOR)
- Check for visible damage.
- Check for oil leaks in the hydraulic unit, lines and cylinder. Check battery capacity on the battery condition meter
Since this is a battery operated system, the battery capacity will have to be checked on a daily basis.
When the main switch is ON (1) the capacity is monitored by the battery condition meter.
It is advised to recharge the batteries when they are below the ½ full indication.
Under normal conditions batteries need to be recharged after 12 to 15 full load cycles.
Recharging an empty battery will take 12 to 16 hours.
Each column is provided with with an automatic battery charger . the charger can beconnected to mains by means
of the universal IEC connection on the front. (115V/60Hz/ 2Amp)
The charger is independent of the control system. This means that the main switch can be turned off while charging.
Summary of Contents for ST 1082-F/BAT
Page 1: ...Mobile Column Lifts ST 1082 F BAT ST 1082 R BAT Installation operation service 32738980 A ...
Page 2: ......
Page 14: ...10 ...
Page 31: ...27 MICROPROCESSOR BOARD Fig 8 1 Location of fault indication LED s ...
Page 37: ...33 FIG A ...
Page 39: ...35 FIG B Item 6 locked with loctite 542 sealant ...
Page 42: ...38 FIG E CONTROL BOX ...
Page 44: ...40 FIG F SCHEMATIC DIAGRAM ...
Page 51: ......