15
The control system of the mobile column lift is set-up as follows:
1. Connect the lifting columns in a full circuit as indicated in 5.2, Connecting Lifting Columns.
- The column sequence in this circuit can be selected at random columns can be
positioned at any place, provided the maximum lifting capacity of 72,000 lbs is not exceeded as described in
5.2.
- The maximum number of lifting columns in a system is 28
2. With respect to all columns:
- Set main switches to 1 (ON).
3. Take care that the emergency stop button of each lifting column has been released.
4. Press the "SET REF" button.
The light in button 8 (control power) will come on indicating that:
- the system control has been checked for its proper functioning
- the sequence of all lifting columns has been stored in the system memory
- the primary column in the system has been connected to the mains.
5. Press the "SET REF" button again.
The light in this button will come on indicating that:
- the height position of each lifting column has been stored in the system.
- the lifting columns can now be activated.
All functions are possible now except paired operation.
6. Setting paired operation (only possible with an even number of lifting columns):
- Select the primary columns at one axle to set this function (e.g. the front wheel axle).
- Press the "SET AXLE" button on one of the lifting columns belonging to the selected axle for approx. 3
seconds.
- The "SET AXLE" button will flash indicating that the setting procedure has been selected.
- Within 30 seconds press the "SET AXLE" button of the control panel of the lifting column on the other side
of the axle and also keep it pressed for 3 seconds.
The "SET AXLE" buttons of all lifting columns will go on indicating that paired operation has been set.
When setting paired operation, the other pairs of axles in the control system are automatically selected as pairs.
This only works satisfactorily if all lifting columns have been connected in a closed circuit as described in 5.2.
All system functions are now available by pressing:
- button 3
⇑
, all columns are raised;
- button 4
⇓
, lowered and locked;
- buttons 6 and 4
⇓
, all columns are lowered;
- buttons 5 (SET AXLE) and 3
⇑
, one axle is raised (2 lifting columns);
- buttons 5 (SET AXLE) and 4
⇓
, one axle is lowered (2 lifting columns);
- buttons 7 (SET REF) and 3
⇑
, one column is raised;
- buttons 7 (SET REF) and 4
⇓
, one column is lowered.
Note: In case of using one or two lifting columns (in paired operation), be sure that this will not result in stability risks. In
case of doubt, consult your superior. Unsafe lifting can result in serious injury and damage to the lifting system and/or
vehicles. (see also 5.8)
Summary of Contents for ST 1082-F/BAT
Page 1: ...Mobile Column Lifts ST 1082 F BAT ST 1082 R BAT Installation operation service 32738980 A ...
Page 2: ......
Page 14: ...10 ...
Page 31: ...27 MICROPROCESSOR BOARD Fig 8 1 Location of fault indication LED s ...
Page 37: ...33 FIG A ...
Page 39: ...35 FIG B Item 6 locked with loctite 542 sealant ...
Page 42: ...38 FIG E CONTROL BOX ...
Page 44: ...40 FIG F SCHEMATIC DIAGRAM ...
Page 51: ......