13
• Mechanical safety lock
If the hydraulic pressure fails while a vehicle is on the lifting system or is lifted or lowered,
a mechanical safety lock ensures that it cannot drop.
The characteristic clicking of the safety lock when lifting, indicates that it is activated.
During lowering the pawl is retracted by a solenoid.
• Adjustable forks (option)
The forks can be adjusted manually to accommodate a wide range of tire sizes. A mechanical lock prevents the
forks from moving sideways under load.
4.
INSTALLATION
Remark: Only move the lifting column with the correct type of lifting equipment.
Only raise the lifting column at the correct points. Damage to lifting column and/or injury to
persons may occur if the lifting column is not moved in the correct manner.
4.1
UNPACKING AND HANDLING THE LIFTING COLUMN
1. Transport the lifting column to the place of use.
2. Remove the cover from the crate or, when using a stand, remove the straps.
Remark: Do not stand under the lifting column when it is suspended from the lifting equipment. If it falls it
will cause serious injury.
3. Fasten a sling with a hoisting capacity of at least 1100
lbs around the lifting column and lift the column from
the crate (see fig. 4.1).
4. Carefully lower the lifting column to the floor.
5. Attach a sling at the top of the column.
6. Lift the column to the upright position.
7. Remove the sling from column.
For transport the complete assembly (incl. hydraulic unit)
is taken from the column.
8. The assembly can be lifted by two man, and can be hung
on the existing bracket for the hydraulic unit on the
column.
9. Remove the two bolts on the left side to open the hinged
cover.
10. Fix the frame with 3x M6 bolt to the column.
11. Reconnect potentiometer plug.
12. Reconnect unlock solenoid plug.
13. Reconnect hydraulic hose (bleed air later on top of
cylinder, if req'd).
14. Position batteries with + connection to the right when
looking into the door (see picture page 38).
15. Make sure main switch is off and connect batteries.
16. Use the threaded bar to retain the batteries and to line-up
the M6 holes for closing the cover.
17. Connect columns with cables.
18. Remove the plug from the fill opening and install the
breather cap. Close the hinged cover.
19. Check for oil leakage.
20. Repeat the procedure for each column.
Fig. 4.1
Summary of Contents for ST 1082-F/BAT
Page 1: ...Mobile Column Lifts ST 1082 F BAT ST 1082 R BAT Installation operation service 32738980 A ...
Page 2: ......
Page 14: ...10 ...
Page 31: ...27 MICROPROCESSOR BOARD Fig 8 1 Location of fault indication LED s ...
Page 37: ...33 FIG A ...
Page 39: ...35 FIG B Item 6 locked with loctite 542 sealant ...
Page 42: ...38 FIG E CONTROL BOX ...
Page 44: ...40 FIG F SCHEMATIC DIAGRAM ...
Page 51: ......