Service and Parts manual (Version B)
60
Wireless
The user settings screen appears.
2.
Press the second button at the bottom of the settings screen.
The second user settings screen appears.
3.
Position the column at the required height.
4.
Lower the column lift into the pawls and then raise it approx. 25 mm, to make sure
that the highest position is well above the locking position.
5.
Enable the programmable height limit function (set it [ON]) and exit the service
menu. The setting is switched [ON] for all the columns in the set. The current
height is set as the height limit for each column, even if the current height has been
set higher or lower with the [SINGLE] or [PAIR] functions. This therefore means
that the other columns can have a height limit that is different from the height limit
for the column that they were adjusted to.