Service and Parts manual (Version B)
33
Wireless
Maintenance tasks Description
Monthly Per year
(technical
service)
Every
2 years
(technical
service)
Safety lock
Disassemble, clean and
replace (if necessary),
and adjust; see section
.
X
5.5.2
Hydraulic oil
Replace the hydraulic oil in the tank approximately once every 2 years.
NOTE
This oil change must take place as scheduled, even when the column lift is not
being used continuously.
When changing the hydraulic oil, proceed as following:
1.
Fully lower the column lifts and drain off the oil.
2.
Fill the tank with hydraulic oil filtered at maximum 4 microns.
Table 3: Hydraulic oil type
Oil type
Oil name
Standard
Unil HVC SX 15
Alternative
Mobil DTE 10
Excel 15
Biodegradable
Panolin SYNTH 15 (on customers request)
The different types of oils should not be mixed.
NOTE
After draining the oil and refilling the system with new oil, a low mix percentage
is allowed. However, warranty will expire when not prescribed oil is used and / or
different types of oils are mixed.
Table 4: Quantity of hydraulic oil in the tank
Column type
Quantity (liters)
ST 1065
10
ST 1075
8