5.5.3
Checking the emergency shutdown mechanism
1.
Press the emergency shutdown button on the auxiliary cabinets while the column
lifts are moving. All column lifts must immediately come to a standstill.
2.
Turn the emergency stop knob counter clockwise to release it.
3.
Press [SELECT] and the release button simultaneously for 2 seconds; the
emergency stop situation is canceled and the system is ready to be used again.
5.5.4
Checking the safety locking feature
fig. 3: Checking the safety locking feature
1.
Lower the column lifts completely, if necessary, use the switches S1 through S4 on
the control panel; see also section Control box sticker.
2.
Raise the column lifts to the first safety lock, then lower them into the safety lock.
Check whether the free play of the adjustment nut of the solenoid is 3 to 4 mm.