Service and Parts manual (Version B)
70
Wireless
Code Screen text
Possible cause
Solution
08
Another column is on
the configuration menu.
Operator on other
column is changing
parameters.
Wait for this operator to
finish the action.
10
Foot guard limit
reached.
The foot guard limit has
been reached.
Lower the columns to
reach ground level.
12
Battery overcharged.
Overcharged voltage
defect.
Check battery charger
for proper operation.
Voltage may not exceed
30V.
21
Brief communication
loss.
Column has lost contact
with at least one
column. System tries to
reconnect.
Wait for reconnection
or start up the system
again.
22
PWM output timeout.
-
-
23
Remote crush limit
exceeded
Remote crush limit was
exceeded
Lowering with remote is
not possible anymore.
Use the buttons on
the car lift to lower the
vehicle.
25
Communication
lost during settings
synchronization
Communication
problems to other
columns during
transferring the settings
to other columns.
Restart the system
26
Configuration
Error
Different configuration
settings in one set…
Check settings
27
Ground level reached.
Column reached the
ground level.
Press the down button
again to put all columns
on the ground.
28
Another group sends on
the same frequency
-
-
89
Column on
Wheels
Column is on wheels.
Lower the column and
make new set.
Summary of Contents for ST 1065-FWF