SSD6000-SSD6000S-SE6000D4
23
Drop the main control panel forward and check for any loose, broken, burnt wiring.
Component test the MCB,RCD and voltage selector switch.
Battery
Low Oil Level
● Check oil level and top-up to the correct level
if necessary.
Oil Pressure Switch
●
Check the oil pressure switch operation -
Switch normally closed when engine is at rest
and open when engine running - Remove,
clean or replace if necessary.
Faulty Wiring
● Check associated wiring from the oil pressure
switch to the DSE 3110.
Fault Icon
Possible Cause
Low Oil Pressure
Check
Service
● Oil change and oil filter clean recommended.
Canopy Obstructions
●
Has the engine overheated? - Check the
generator canopy has no obstructions over any
vented areas - Also see
Operating
Environment
in this handbook.
Fault occurs after
the engine has
fired
AC Output Fault
Generator starts
and runs but
there is no output
from the AC
socket outlets
MCB & RCD
● Check the MCB & RCD are switched on (up).
Voltage Selector Switch
● Check the voltage selector switch is in the
correct position.
Reset Button(s)
● Check the reset buttons for the output
sockets.
Fault occurs after
the engine has
fired
Temperature Switch
●
Check the temperature switch operation -
Disconnect both wires and link together to test
- replace if necessary -
DO NOT USE WITHOUT
A TEMPERATURE SWITCH FITTED
.
High Engine
Temperature
Faulty Wiring
● Check associated wiring from the
temperature switch to the DSE 3110.
See
BATTERY CHARGE FAULT FINDING
-
DSE 3110 TYPE
Charge Fail
Battery Flat & Not
Charging
Battery Charge System Fault Finding
When a battery charging fault has occurred the battery lamp on the control panel should be illuminated
when the generator/engine is running.
Firstly measure the DC voltage directly at the battery while the generator is at standstill, this should be
around 12.5v DC. Test the battery and replace if necessary.
Start and run the generator. Once the set is up and running the DC voltage at the battery should measure
anything from 13.5 to 15.0v DC in normal operation - If the measured voltage is below 13.0V after 5 minutes
of running continue with the fault finding.