SSD6000-SSD6000S-SE6000D4
14
● Diesel fuel is extremely flammable and explosive under certain conditions.
● Only fill the fuel tank with diesel fuel.
● NEVER refuel with the generator running.
● Wipe up all spills immediately.
● NEVER overfill the fuel tank.
● ALWAYS ensure the fuel cap is secure after refuelling.
On the 3 Phase version, ensure the main 4 pole
RCBO
is in the
OFF
position (switch down).
Fig.10
shows the key start controls for the generator.
No.
Fig.10
Check Fuel Level
Ensure there is enough fuel in the fuel tank. All the generator models in this handbook have a "Low Fuel
Level" switch. When you turn the key switch to the first position "RUN" and the red "Low Fuel Level" LED is
illuminated, this would indicate that there not enough fuel in the fuel tank and the generator will not be able
to be started.
HIGH ENGINE TEMP
- When illuminated, indicates the
engine has overheated.
LOW OIL PRESSURE
- LED illuminates when the engine
oil pressure is low.
Ensure the main double pole
MCB
and
RCD
(single phase and dual voltage versions) are in the
OFF
position
(switch down).
WARNING
-
NEVER
try to start the generator with load connected.
Key Start Controls
Description
4
2
20A RESET
- Thermal circuit breaker protecting the
12V system.
3
BATTERY
- LED illuminates when the battery is not
being charged from the engine charging system.
Main Circuit Breaker - MCB, RCD & RCBO
Filling the Fuel Tank
● Keep sparks, open flames or any other form of ignition (match,cigarette, static electric source) away when
fueling / refueling.
1
KEY SWITCH
- Used to start and stop the generator.
5
6
LOW FUEL LEVEL
- Will illuminate when the fuel level
is low in the fuel tank.
1
2
3
4
5
6