Lamps
●
Check the engine oil level.
●
Check the correct engine oil has been used.
HIGH ENGINE TEMP
When the key is turned to the
RUN
position
the
BATTERY
and
HIGH ENGINE TEMP
lamps
are illuminated.
●
Has the engine overheated? - Check the generator
canopy has no obstructions over any vented areas - Also
see
Operating Environment
in this handbook.
●
Check the temperature switch operation - Disconnect
both wires and link together to test - replace if necessary -
DO NOT USE WITHOUT A TEMPERATURE SWITCH FITTED.
●
Check the temperature relay operation - Replace if
necessary.
BATTERY
Once the generator has started and is running
the
BATTERY
lamp remains illuminated.
This could indicate that the battery charging system has a
fault.
●
Check the fuse next to the charge regulator (white fuse
holder) or See Battery Charge System Fault Finding in this
handbook for comprehensive testing.
Basic Trouble Shooting - Key Switch Type
Fault Description
Checks & Tests
LOW OIL PRESSURE
The starter motor cranks when the key is in
the
START
position and the engine runs but
the
LOW OIL PRESSURE
lamp remains
illuminated. When the key is returned to the
RUN
position the generator stops. The
BATTERY
and
LOW OIL PRESSURE
lamps are
illuminated.
●
Check the oil pressure switch operation - Switch normally
closed when engine is at rest and open when engine
running - Replace if necessary.
●
Check the oil pressure relay operation - Replace if
necessary.
●
Check associated wiring with the oil pressure switch &
relay.
LOW FUEL LEVEL
When the key is turned to the
RUN
position
the
BATTERY
and
LOW FUEL LEVEL
lamps are
illuminated.
●
Check the fuel level - Fill the fuel tank with a minimum
10L of diesel.
●
Check the fuel level switch operation - Disconnect to test
and replace if necessary.
●
Check the fuel level relay operation - Replace if
necessary.