16400-7820 GIDOD REV A

3 - SPECIFICATIONS

A. IDOD SEE THROUGH DIMENSIONS - EXTERIOR

B-E

 C

 D 

 7 1/2

[190] 

1

[25] 

 N

25 9/16

[649]

OVERALL DEPTH

WITH DECORATIVE

FRAMES

Model # (INCHES/MILLIME-

TERS)

Viewing Area 

Width

Viewing Area

Height

Glass Frame

Width

Glass Frame 

Height

Glass Frame 

Height With 

OD Intake

Outer Flange 

Width

Outer Flange

Height

H

I

J

K

L

M

N

24" HIGH GLASS

3-IDOD-2-GL

36 

[914]

24 

[610]

42-5/32 

[1,071]

29-5/8 

[752]

34-17/32 

[877]

46-15/16 

[1,192]

58-7/32 

[1,479]

4-IDOD-2-GL

48 

[1,219]

24 

[610]

54-5/32 

[1,375]

29-5/8 

[752]

34-23/32 

[882

58-15/16 

[1,497]

58-7/32 

[1,479]

5-IDOD-2-GL

60 

[1,524]

24 

[610]

66-5/32 

[1,680]

29-5/8 

[752]

34-23/32 

[882

70-15/16 

[1,802]

58-7/32 

[1,479]

6-IDOD-2-GL

72 

[1,829]

24 

[610]

78-5/32 

[1,985]

29-5/8 

[752]

34-23/32 

[882

82-15/16 

[2,107]

58-7/32 

[1,479]

7-IDOD-2-GL

84 

[2,134]

24 

[610]

90-5/32 

[2,290]

29-5/8 

[752]

34-23/32 

[882

94-15/16 

[2,411]

58-7/32 

[1,479]

8-IDOD-2-GL

96 

[2,438]

24 

[610]

102-5/32 

[2,595]

29-5/8 

[752]

34-23/32 

[882

106-15/16 

[2,716]

58-7/32 

[1,479]

36" HIGH GLASS

3-IDOD-3-GL

36 

[914]

36 

[914]

42-5/32 

[1,071]

41-5/8 

[1,057]

46-17/32 

[1,182]

46-15/16 

[1,192]

70-7/32 

[1,783]

4-IDOD-3-GL

48 

[1,219]

36 

[914]

54-5/32 

[1,375

41-5/8 

[1,057]

46-23/32 

[1,187]

58-15/16 

[1,497]

70-7/32 

[1,783]

5-IDOD-3-GL

60 

[1,524]

36 

[914]

66-5/32 

[1,680]

41-5/8 

[1,057]

46-23/32 

[1,187]

70-15/16 

[1,802]

70-7/32 

[1,783]

6-IDOD-3-GL

72 

[1,829]

36 

[914]

78-5/32 

[1,985]

41-5/8 

[1,057]

46-23/32 

[1,187]

82-15/16 

[2,107]

70-7/32 

[1,783]

7-IDOD-3-GL

84 

[2,134]

36 

[914]

90-5/32 

[2,290]

41-5/8 

[1,057]

46-23/32 

[1,187]

94-15/16 

[2,411]

70-7/32 

[1,783]

8-IDOD-3-GL

96 

[2,438]

36 

[914]

102-5/32 

[2,595]

41-5/8 

[1,057]

46-23/32 

[1,187]

106-15/16 

[2,716]

70-7/32 

[1,783]

I

 H

L

J

A

K

 3 [76]

M

EXTERIOR FRONT VIEW

Summary of Contents for 3-IDOD-2-GL

Page 1: ...ch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier c...

Page 2: ...perating the fireplace Installers please leave manual for the homeowner to use for future reference Please have the fireplace model information available when contacting Stellar Hearth for additional...

Page 3: ...ervent Specifications 27 G In line Powervent Preparations RSIF 180 28 H Horizontal Vent System Clearance 29 I Wall Pass Through 29 J Pitot Tube Information 29 8 Venting Continued K Vertical Terminatio...

Page 4: ...ed service technician Clean glass only when cool and only with non abrasive cleansers Do not operate this appliance with the glass frame assembly removed cracked or broken Replacement of the glass ass...

Page 5: ...fueled heating appliance or equipment The sign shall read in print no less the one half inch 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspe...

Page 6: ...9 8 IDOD 2 GL 10 12 102 17 32 2 604 30 762 34 23 32 2 600 42 1 32 1 067 51 1 295 51 1 4 1 302 24 610 102 17 32 2 604 36 HIGH GLASS 3 IDOD 3 GL 8 10 42 17 32 1 080 36 914 46 23 32 1 187 54 1 32 1 372 6...

Page 7: ...5 8 752 34 23 32 882 82 15 16 2 107 58 7 32 1 479 7 IDOD 2 GL 84 2 134 24 610 90 5 32 2 290 29 5 8 752 34 23 32 882 94 15 16 2 411 58 7 32 1 479 8 IDOD 2 GL 96 2 438 24 610 102 5 32 2 595 29 5 8 752...

Page 8: ...19 32 2 27 32 1 11 16 1 5 13 32 2 29 32 13 7 32 21 3 32 2X 3 13 16 2X 6 13 16 2X 8 5 16 7 8 1 3 32 3 GAS KNOCK OUT ELECTRICAL ELECTRICAL ELECTRICAL 3 GAS KNOCK OUT ELECTRICAL GAS KNOCK OUT GAS KNOCK O...

Page 9: ...11 16 1 5 13 32 2 29 32 13 7 32 21 3 32 2X 3 13 16 2X 6 13 16 2X 8 5 16 3 GAS KNOCK OUT 7 8 ELECTRICAL KNOCK OUTS 1 3 32 ELECTRICAL KNOCK OUTS 3 GAS KNOCK OUT GAS KNOCK OUT GAS KNOCK OUT ELECTRICAL KN...

Page 10: ...e collar Framing must allow for vent installation 2 If masonry optional will be used prepare foundation for the masonry load A lintel is required to support the added weight above the fireplace 3 Inst...

Page 11: ...placed at the top of the viewing area Do not overlap glass A combustible hearth extension may be used below the viewing area on the interior side and below the outside air vents on the exterior side D...

Page 12: ...andoff up and both ends out at the perforated lines Using Figure 3A 2 for reference locate the second pre installed screw on the firebox top at each standoff location Remove the screw pivot the folded...

Page 13: ...ickness and fireplace facing materials When using a hearth adjust rough opening size as necessary to maintain at least minimum clearance requirements If masonry is to be used optional prepare the nece...

Page 14: ...68 17 32 2 046 68 17 32 2 046 6 IDOD 3 GL 54 1 32 1 322 63 1 600 69 1 753 80 17 32 2 046 80 17 32 2 046 7 IDOD 3 GL 54 1 32 1 322 63 1 600 69 1 753 92 17 32 2 350 92 17 32 2 350 8 IDOD 3 GL 54 1 32 1...

Page 15: ...steel 3 76 surface all around the fireplace opening can not be covered with any type of material Glass and decorative framing will be placed on top E EXTERIOR INTERIOR 5 FRAMING MANTEL REQUIREMENTS I...

Page 16: ...the combustible framing the full width of the fireplace The space includes a 7 178mm minimum above the top of the fireplace that is recommended for ease of attachment 15 381 for 3 7 units and 19 483 f...

Page 17: ...NTEL TOP OF FIREPLACE 1 2 12 7 CLEARANCE TO COMBUSTIBLES ON HOOD SURFACE The fireplace ships with standoffs in place to ensure a 1 2 clearance to combustibles is maintained on the surface 3 76 2mm THE...

Page 18: ...f the fireplace that is recommended for ease of attachment 15 381 for 3 7 units and 19 483 for 8 units Refer to Figure 5 2 below for requirements when not using the provided 1 2 standoffs Refer to Fig...

Page 19: ...AND DECORATIVE FRAMING WILL BE PLACED ON TOP OF IT EXTERIOR TOP GLASS FRAME DO NOT COVER COMBUSTIBLE FRAMING 12 305 COMBUSTIBLE MANTEL 7 ABOVE TOP OF FIREPLACE If the standoffs are removed only non co...

Page 20: ...ING FROM FIREPLACE AND BECOMING DAMAGED FOLLOW THE INSTRUCTIONS EXACTLY WHEN REMOVING AND INSTALLING GLASS FRAME ASSEMBLY STOP DO NOT OPERATE THIS FIREPLACE WITH THE GLASS REMOVED CRACKED OR BROKEN RE...

Page 21: ...ght vertical filler trim pieces Figure 6B 3 Align the screw holes on the filler pieces to the fireplace B GLASS TRIM PIECES BOTH INTERIOR AND EXTERIOR 6 GLASS FRAME ASSEMBLY Figure 6B 1 Figure 6B 2 Fi...

Page 22: ...ECORATIVE FRAME ASSEMBLY D INTERIOR DECORATIVE GLASS FRAME The interior side glass trim now simply sits in front of the interior outer glass assembly and is held on by the round magnets The interior s...

Page 23: ...rior outer glass frame assembly will have bolt holes around the perimeter Set the glass in place such that the holes align with the holes on the exterior face of the fireplace Affix with the supplied...

Page 24: ...e testing of that system at pressures in excess of psi NOTE The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing...

Page 25: ...er to the vent systems manufacturer s installation manual for complete installation instructions Installation must conform with the venting requirements and restrictions as outlined in this manual SEE...

Page 26: ...in mm 14 3 364 16 6 422 Dimension C in mm 13 5 344 15 5 395 Dimension D in mm 3 3 85 3 9 100 Dimension E in mm 11 6 294 13 5 342 Temperature Rating Intermittent 575 F 300 C 575 F 300 C Temperature Rat...

Page 27: ...EFC Voltage VAC 1 x 120 1 x 120 Amperage Amps 2 9 5 3 Motor Output hp kW 3 7 32 13 16 61 RPM 1600 1600 Weight lbs kg 38 17 60 27 Duct Connection E in mm 8 203 8 203 Dimension A in mm 14 57 370 16 15 4...

Page 28: ...nt The pre drilled screw holes within the circle will be matched with the holes on the intake collar of the base plate See Figure 8G 3 3 Place the intake collar base plate onto the silhouette matching...

Page 29: ...8 VENTING 8 VENTING J PITOT TUBE INFORMATION There is a 1 4 pitot tube mounted in the center of the flue collar and is connected to the pressure switch Figure 8E This monitors the pressure in the flu...

Page 30: ...regulator assembly within 3 ft 914 mm horizontally from the center line of the regulator I Gas Service regulator vent outlet 3 ft 914 mm J Non mechanical air supply inlet to building or the combustion...

Page 31: ...combustible I Combustible Non combustible 12 305mm C Clearance from corner in recessed location Combustible 24 609 6mm Non combustible 12 304 8mm D Minimum width for back wall of a recessed location...

Page 32: ...INS_CUST UL REV E Page 32...

Page 33: ...O 10 12 2 5 0 76 OVER 10 12 TO 11 12 3 25 0 99 OVER 11 12 TO 12 12 4 0 1 22 OVER 12 12 TO 14 12 5 0 1 52 OVER 14 12 TO 16 12 6 0 1 83 OVER 16 12 TO 18 12 7 0 2 13 OVER 18 12 TO 20 12 7 5 2 27 OVER 20...

Page 34: ...EL CHIMNEY ADAPTER INSULATION PAD MUST BE CUT IN CENTER TO ACCOMMODATE VENT SIZE Roof Termination Without Optional Mechanical Damper Figure 8P 1 POWERVENT MOUNTING BRACKETS OR DRILL MOUNTING HOLES TO...

Page 35: ...LATION PAD MUST BE CUT IN CENTER TO ACCOMMODATE VENT SIZE MECHANICAL FLUE DAMPER Figure 8Q 2 DRILL 1 4 HOLES TO MATCH POWER VENT BASE USE APPROPRIATE HEAVY DUTY FASTENERS TO SECURE POWER VENT INSULATI...

Page 36: ...air intake vents are located on the exterior face of the fireplace Must not be obstructed by finishing materials If a hearth is used it has to be placed below the air intake vents You must properly fl...

Page 37: ...haust and Air Intake LOUVER 10 6 7 Exhaust and Air Intake FOLLOW COMPLETE INSTALLATION INSTRUCTIONS PROVIDED WITH THE LOUVER KIT 22 1 4 565mm 22 1 4 565mm 18 457mm A LOUVER 8 7 7 8 IN LOUVER 10 9 7 8...

Page 38: ...SURE SWITCH 4 SIDED ONLY 14 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH 4 SIDED ONLY NOTES 120 VOLT LOOP 120 VOLT LOOP 120 VOLT LOOP 120 VOLT LOOP CONNECT TO CONSTANT POWER SOURCE CONNECT TO CONSTANT...

Page 39: ...IF EQUIPPED 10 24VAC FLUE DAMPER NEUTRAL IF EQUIPPED 11 SW3 FLUE DAMPER PROVE ONLY IF DAMPER IS USED 12 SW3 DAMPER PROVE ONLY IF DAMPER IS USED 13 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH 4 SIDED...

Page 40: ...INS_CUST UL REV E Page 40 10 ELECTRIC Figure 10C 1 Terminals 1 2 C 1 TERMINALS 1 2 LED Lights Figure 10C 2 Terminals 3 4 C 2 TERMINALS 3 4 Main Flame...

Page 41: ...V A 10 ELECTRIC GROUND LOCATE THE GREEN WIRE CLUSTER CONNECT THE GREEN WIRE TAIL TO BUILDING GROUND Figure 10C 3 Terminals 5 6 C 3 TERMINALS 5 6 Fireplace Power Figure 10C 4 Terminals 7 8 C 4 TERMINAL...

Page 42: ...TOR BLACK WIRE TERMINAL 10 IS THE HOT CONNECTION FOR THE DAMPER MOTOR RED WIRE THIS IS LOW VOLTAGE AND EXTERNAL POWER MUST NOT BE APPLIED TERMINALS 9 10 FLUE DAMPER CONNECTION NOTE OPTIONAL IF A DAMPE...

Page 43: ...gure 10C 6 Terminals 11 12 C 6 TERMINALS 11 12 OPTIONAL Flue Damper Connection NOTE OPTIONAL IF A DAMPER IS NOT USED TERMINALS 11 AND 12 HAVE A JUMPER ACROSS THEM NOTE RED IS NOT USED AND SHOULD BE SA...

Page 44: ...2 C Combustible material may cover the non combustible area mentioned in B D Combustible finishing materials allowed E Combustible mantel may be placed above the top of the decorative frame area There...

Page 45: ...r ease of attachment 15 381 for 3 7 units and 19 483 for 8 units See Figure 10A 2 C Combustible material may cover the non combustible area mentioned in B D Combustible finishing materials allowed E C...

Page 46: ...tible hearth may be placed below the bottom of the decorative glass frame area F G IN Flat covers will cover the components access Gas and electric inlets are located behind this panel There are three...

Page 47: ...for ease of attachment 15 381 for 3 7 units and 19 483 for 8 units See Figure 10A 2 C Combustible material may cover the non combustible area mentioned in B D Combustible finishing materials allowed E...

Page 48: ...under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water WHAT TO DO IF YOU SMELL GAS Do not touch a...

Page 49: ...lace on at switch OFF 2 ON 5 Figure 12B 12 LIGHTING SHUTDOWN STOP Read safety information on previous page and front cover of this manual before continuing NOTE This fireplace is equipped with an igni...

Page 50: ...NOT SUBSTITUTE THE SUPPLIED MEDIA WITH ANY OTHER KIND OF MEDIA WITHOUT WRITTEN APPROVAL OF STELLAR HEARTH PRODUCTS Figure 14A NOTE The appliance and its individual shutoff valve must be disconnected...

Page 51: ...he inner and outer glass panels Remove the glass media on the end with the pilot The end floor lifts out remove the screws and lift it out Remove the burner and loosen the pilot bracket There is a pan...

Page 52: ...9 bags 6 11 bags 7 13 bags 8 15 bags PART PART NUMBER 8 Inch Exhaust Collar 16400 1450 10 Inch Intake Exhaust Collar 16400 1550 12 Inch Intake Collar 16800 1550 LED Transformer 16400 1900 LED Controll...

Page 53: ...1844 2 4 IDOD 3 GL SRV20200 1945 4 SRV20200 1844 2 5 IDOD 2 GL SRV20200 1925 4 SRV20201 1844 2 5 IDOD 3 GL SRV20200 1945 4 SRV20201 1844 2 6 IDOD 2 GL SRV20200 1925 4 SRV20202 1844 2 6 IDOD 3 GL SRV2...

Page 54: ...the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributo...

Page 55: ...cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is no...