X
Y
23 [584]-X-Y
C
Z
A
1
1/2 [13]
B
7 [178] ****
23 [584] *
C
6 [152] **
EXTERIOR
INTERIOR
5 - FRAMING & MANTEL REQUIREMENTS
Refer to
Section 5 (Non-combustible Zone)
for more
information on the 1/2" [13] clearance standoffs.
INCHES [MM]
Firebox
Top Height
Overall
Height
Framing
Height
Interior
Framing
Width
Exterior
Framing
Width
A
B
C
D
E
3-IDOD-2-GL
42-1/2
[1,068]
51
[1,295]
57
[1,448]
44-17/32
[1,131]
44-17/32
[1,131]
4-IDOD-2-GL
42-1/2
[1,068]
51
[1,295]
57
[1,448]
56-17/32
[1,436]
56-17/32
[1,436]
5-IDOD-2-GL
42-1/2
[1,068]
51
[1,295]
57
[1,448]
68-17/32
[2.046]
68-17/32
[2.046]
6-IDOD-2-GL
42-1/2
[1,068]
51
[1,295]
57
[1,448]
80-17/32
[2,046]
80-17/32
[2,046]
7-IDOD-2-GL
42-1/2
[1,068]
51
[1,295]
57
[1,448]
92-17/32
[2,350]
92-17/32
[2,350]
8-IDOD-2-GL
42-1/2
[1,068]
51
[1,295]
57
[1,448]
104-17/32
[2,655]
104-17/32
[2,655]
3-IDOD-3-GL
54-1/32
[1,322]
63
[1,600]
69
[1,753]
44-17/32
[1,131]
44-17/32
[1,131]
4-IDOD-3-GL
54-1/32
[1,322]
63
[1,600]
69
[1,753]
56-17/32
[1,436]
56-17/32
[1,436]
5-IDOD-3-GL
54-1/32
[1,322]
63
[1,600]
69
[1,753]
68-17/32
[2.046]
68-17/32
[2.046]
6-IDOD-3-GL
54-1/32
[1,322]
63
[1,600]
69
[1,753]
80-17/32
[2,046]
80-17/32
[2,046]
7-IDOD-3-GL
54-1/32
[1,322]
63
[1,600]
69
[1,753]
92-17/32
[2,350]
92-17/32
[2,350]
8-IDOD-3-GL
54-1/32
[1,322]
63
[1,600]
69
[1,753]
104-17/32
[2,655]
104-17/32
[2,655]
YOU WILL NEED TO DETERMINE
THE DEPTH DIMENSION FOR YOUR
INSTALLATON BASED ON THE
THICKNESS OF THE
FINISHING AND FRAMING
MATERIALS YOU ARE USING.
Figure 4.1 Front View
Figure 4.1 Right Side View
X - WALL SHEATHING THICKNESS
Y = WALL FRAMING THICKNESS
Z = INTERIOR SHEATHING PLUS FINISH THICKNESS
* 23" [584] is the dimension from the back of the
nailing flange to the tip of the interior clearance
standoff. Interior framing will shift based on material thickness.
** There is a 1" [25] clearance to combustibles around the flue.
Framing thickness (X + Y) must be observed to maintain this
clearance or a 45 degree vent component must be used.
*** Install mineral wood insulation in the 1" [25] gap between the
fireplace sides and wall. Do not use fiberglass or any type of
insulation with paper or plastic facing.
**** Mineral wool may be installed between the
fireplace top and header. Do not use fiberglass or any type of
insulation with paper or plastic facing.