Technical Data
9.0
7
Select Timed Click:
Selection in this mode is dependent on duration and number of clicks.
- For outputs 1 to 3, keep the input closed to scan the outputs. A number of beeps and
corresponding LED will be activated.
- Output 1: Short press (<
Select/Scan Time
)
- Output 2: Medium Press (>
Select/Scan Time
)
- Output 3: Long Press (>2x
Select/Scan Time
)
- For output 4, double click (within the
Select/Scan Time
)
When the desired output is indicated, release the input again to select and activate the
output.
-
The output will remain closed for a set time (depending on the output's 'Close Time' settings), or
-
the output will remain locked until it is manually deselected (depending on the output's 'Lock'
setting).
(
Note:
If too much time elapsed without selecting and activating an output, the selection process will stop and no
output will be activated. This is a built-in feature designed to allow any unwanted input to be canceled.
Continuous Scan:
In this mode the active outputs are scanned continuously.
When the desired output is indicated, close the input to select and activate the output.
-
The output will remain closed as long as the input is closed, or
-
The output is locked until released (depending on the output's 'Lock' setting)
- The output will remain closed as long as the input is closed, or
- the output will remain locked until it is manually deselected (depending on the output's 'Lock'
setting).
(
Note:
If too much time elapses without selecting and activating an output, the selection process will stop and no
output will be activated. This is a built-in feature designed to allow any unwanted input to be canceled.)