Technical Data
9.0
6
Click Mode:
To generate one or more short clicks, quickly open and close (activate and deactivate) the
input.
(The period between the clicks has to be shorter than the 'Action Delay' time.)
After the clicks are input,
- The output will be closed for a set time (depending on the output's 'Close Time' setting), or
- the selected output will remain locked until released (depending on the output's 'Lock' setting).
Start Scan:
A quick click (input activation) will begin a scan of available active outputs.
- A number of beeps corresponding to the number of available active outputs will be generated, and
- a corresponding selection LED will be activated.
When the desired output is indicated, click (activate) the input again to select and activate
the output.
The output will react.
- The output will remain closed as long as the input is closed, or
- the output will remain locked until it is manually deselected (depending on the output's 'Lock'
setting).
The scanning of the outputs is done at an interval of 'Select/Scan Time'.
(
Note:
If too much time elapses without selecting and activating an output, the selection process will stop and no
output will be activated. This is a built-in feature designed to allow any unwanted input to be canceled.
Mode Select
Hold and Scan:
Activating and holding the input will begin a scan of available active outputs.
- A number of beeps corresponding to the selected output will be generated, and
- a corresponding selection LED will be activated.
When the desired output is indicated, release the input to select and activate the output.
The output will react.